COMPLIANCE INFO_1986-2000
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELM
>
124
>
2300 - Underground Storage Tank Program
>
PR0231866
>
COMPLIANCE INFO_1986-2000
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/24/2023 11:28:43 AM
Creation date
6/3/2020 9:53:14 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1986-2000
RECORD_ID
PR0231866
PE
2361
FACILITY_ID
FA0003957
FACILITY_NAME
AT&T California - UE020
STREET_NUMBER
124
Direction
W
STREET_NAME
ELM
STREET_TYPE
St
City
Lodi
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
124 W Elm St
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231866_124 W ELM_1986-2000.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
360
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
t �t <br />SOIL TEST RESULTS <br />Pacific Bell, 124 W. Elm Street <br />Lodi, California <br />(Date: 9-20 & 21, 1988) <br />Method AVO EPA 8020, TPN EPA 8015 MOD <br />TPH <br />B <br />EB <br />T <br />X <br />BORING PPM <br />PPB <br />PPB <br />PPB <br />PPB <br />#1 @ 20' <10 <br /><1.0 <br />0.0 <br /><1.0 <br /><1.0 <br />#1 @ 28' <10 <br />0.0 <br /><1.0 <br /><1.01 <br /><1.0 <br />#2 <br />@ <br />20' <br /><10 <br /><1.0 <br />0.0 <br /><1.0 <br /><1.0 <br />#2 <br />@ <br />28' <br /><10 <br /><1.0 <br /><1.0 <br />0.0 <br /><1.0 <br />#3 <br />@ <br />20' <br /><10 <br /><1.0 <br /><1.0 <br /><1.0 <br /><1.0 <br />#3 <br />@ <br />25' <br /><10 <br /><1.0 <br /><1.0 <br /><1.0 <br /><1.0 <br />Method AVO EPA 418.1 (3550 Extraction) <br />Results of EPA 418.1 indicate a TEPH of 836 PPM at the east end <br />of the tank at 20 feet deep. Other than this one test result and <br />bore hole #3 @ 20' with TEPH of 25 PPM, all other test results <br />including BTX&E are non-detectable. <br />Visual inspection of the soil samples did not indicate any <br />contamination. There was no odor in the samples. <br />Discussion with the laboratory staff indicates that the 3550 <br />extraction method in conjunction with the EPA 418.1 test method <br />identifies all hydrocarbons. The staff also indicates that the <br />TEPH of 836 PPM probably is a heavier hydrocarbon then diesel at <br />CIO -14 range. <br />PAGE 2 <br />TEPH <br />PPM <br />#1 <br />@ <br />20' <br />836 <br />#1 <br />@ <br />28' <br /><1 <br />#2 <br />@ <br />20' <br /><1 <br />#2 <br />@ <br />28' <br /><1 <br />#3 <br />@ <br />20' <br />25 <br />#3 <br />@ <br />25' <br /><1 <br />Results of EPA 418.1 indicate a TEPH of 836 PPM at the east end <br />of the tank at 20 feet deep. Other than this one test result and <br />bore hole #3 @ 20' with TEPH of 25 PPM, all other test results <br />including BTX&E are non-detectable. <br />Visual inspection of the soil samples did not indicate any <br />contamination. There was no odor in the samples. <br />Discussion with the laboratory staff indicates that the 3550 <br />extraction method in conjunction with the EPA 418.1 test method <br />identifies all hydrocarbons. The staff also indicates that the <br />TEPH of 836 PPM probably is a heavier hydrocarbon then diesel at <br />CIO -14 range. <br />PAGE 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.