Laserfiche WebLink
MONIA%NG 'SYSTEM CERT I O-_ ION <br /> For Use By All Jurisdictions Within the State of California <br /> Authoil t ry Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be <br /> prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided <br /> to the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems <br /> within 30 days of test date. <br /> A. General Information <br /> Facility Name: PACIFIC BELL GEO PAR# UE-020 CLLC Code: LODICA01 <br /> Site Address: 124 W.ELM STREET City: LORI Zip: <br /> Facility Contact Person: KEN MCDONALD Contact Phone No.: 209-473-5430 <br /> Make/Model of Monitoring System: VEEDER-ROOT TLS-350 Date of Testing/Service: 8/16/02 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the aggropriate boxes to indicatespecific a ui ment ins ected/serviced: <br /> Tank ID: 795 Tank ID: <br /> ®In-Tank Gauging Probe: Model: 847390-107 ❑In-Tank Gauging Probe: Model: <br /> ®Annular Space or Vault Sensor: Model: 794390-420 ❑Annular Space or Vault Sensor Model: <br /> ®Piping Sump/Trench Sensor(s): Model: 794390-352 ❑Piping Sump/Trench Sensor(s): Model: <br /> ®Fill Sump Sensor(s): Model: 794390-352 ❑Fill Sump Sensor(s): Model: <br /> []Mechanical Line Leak Detector. Model: ❑Mechanical Line Leak Detector. Model: <br /> []Electronic Line Leak Detector Model: ❑Electronic Line Leak Detector Model: <br /> ®Tank Overfill/Mgh-level Sensor: Model: 790091-001 ❑Tank Overfill/High-level Sensor: Model: <br /> ❑Other, S eci ui . e and model in Section E on Pa e 2 ❑Other,S eci ui a and model in Section E on Page 2 <br /> Tank ID: Tank ID: <br /> ❑In-Tank Gauging Probe: Model: ❑In-Tank Gauging Probe: Model: <br /> []Annular Space or Vault Sensor: Model: ❑Annular Space or Vault Sensor Model: <br /> []Piping Sump/Trench Sensor(s): Model: ❑Piping Sump/Trench Sensor(s): Model: <br /> ❑Fill Sump Sensor(s): Model: ❑Fill Sump Sensor(s): Model: <br /> []Mechanical Line Leak Detector. Model: ❑Mechanical Line Leak Detector. Model: <br /> []Electronic Line Leak Detector Model: ❑Electronic Line Leak Detector Model: <br /> []Tank OverfilUHigh-level Sensor: Model: ❑Tank OverfillMgh-level Sensor: Model: <br /> ❑Other, S eci ui . e and model in Section E on Pa e 2 ❑Other, S eci ui a and model in Section Eon PMe2 <br /> 2 <br /> Dispenser ID: Dispenser ID: <br /> []Dispenser Containment Sensor: Model: []Dispenser Containment Sensor(s): Model: <br /> ❑ Shear Valve(s). ❑ Shear Valve(s). <br /> ❑Dig enser Containment Float(O and Chain(s ❑Dig enser Containment Float(s)and Chains <br /> Dispenser ID: Dispenser ID: <br /> ❑In-Tank Gauging Probe: Model: []Dispenser Containment Sensor(s): Model: <br /> ❑ Shear Valve(s). ❑ Shear Valve(s). <br /> ❑Dis enser Containment Float(s)and Chains FlDisnenser Containment Floats and Chain(s) <br /> Dispenser ID: Dispenser ID: <br /> ❑In-Tank Gauging Probe: Model: []Dispenser Containment Sensor(s): Model: <br /> ❑ Shear Valve(s). ❑ Shear Valve(s). <br /> ❑Dis eraser Containment 1712a,tN and Chain(s) ❑Dis enser Containment Float(s and Chain(s) <br /> *If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the <br /> manufacturers' guidelines. Attached to this Certification is information(e.g.manufacturers'checklists)necessary to verify that this <br /> information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such <br /> reports,I have also attached a copy of the report;(check all that apply): ® System set-up ® rm h' tory resort <br /> Technician Name(Print): BRANDON HAM Signature: <br /> Certification No.: 3435 License No.: 588098 <br /> Testing Company Name: TAIT ENVIRONMENTAL SYSTEMS Phone No.: (714)560-8222 <br /> 03/01 <br /> Page 1 of 3 <br />