My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2001-2005
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELM
>
124
>
2300 - Underground Storage Tank Program
>
PR0231866
>
COMPLIANCE INFO_2001-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/10/2020 12:59:43 PM
Creation date
6/3/2020 9:53:15 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2001-2005
RECORD_ID
PR0231866
PE
2361
FACILITY_ID
FA0003957
FACILITY_NAME
AT&T California - UE020
STREET_NUMBER
124
Direction
W
STREET_NAME
ELM
STREET_TYPE
St
City
Lodi
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
124 W Elm St
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231866_124 W ELM_2001-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
312
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITORING SYSTEM CERTIFICATION <br /> ® For Use By All Jurisdictions Within the State of California <br /> Authority Cited-Chapter 6.7,Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be <br /> prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be <br /> provided to the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating <br /> UST systems within 30 days of test date. <br /> A. General Information <br /> Facility Name: SBC GEO PAR# UE-020 CLLC Code: LODICA01 <br /> Site Address: 124 W. ELM STREET City: LODI Zip: <br /> Facility Contact Person: TOM WILLIAMS Contact Phone No.: 209-578-7178 <br /> Make/Model of Monitoring System: VEEDER ROOT TLS-350 Date of Testing/Service: 8/5/05 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicatespecific a ui ment inspected/serviced: <br /> Tank ID: 1214 Tank ID: <br /> ZIn-Tank Gauging Probe: Model: 847390-107 ❑In-Tank Gauging Probe: Model: <br /> ®Annular Space or Vault Sensor: Model: 794390420 []Annular Space or Vault Sensor Model: <br /> ®Piping Sump/Trench Sensor(s): Model: 794380-352 ❑Piping Sump/Trench Sensor(s): Model: <br /> ®Fill Sump Sensor(s): Model: 794380-352 ❑Fill Sump Sensor(s): Model: <br /> ❑Mechanical Line Leak Detector. Model: ❑Mechanical Line Leak Detector. Model: <br /> ❑Electronic Line Leak Detector Model: ❑Electronic Line Leak Detector Model: <br /> ®Tank Overfill/High-level Sensor: Model: 790091-001 ❑Tank Overfill/High-level Sensor: Model: <br /> ®Other,Specify a ui a and model in Section E on Page 2 ❑Other, Specify e ui a and model in Section E on Page 2 <br /> Tank ID: Tank ID: <br /> ❑In-Tank Gauging Probe: Model: ❑In-Tank Gauging Probe: Model: <br /> ❑Annular Space or Vault Sensor: Model: ❑Annular Space or Vault Sensor Model: <br /> ❑Piping Sump/Trench Sensor(s): Model: ❑Piping Sump/Trench Sensor(s): Model: <br /> ❑Fill Sump Sensor(s): Model: ❑Fill Sump Sensor(s): Model: <br /> []Mechanical Line Leak Detector. Model: ❑Mechanical Line Leak Detector. Model: <br /> ❑Electronic Line Leak Detector Model: [-]Electronic Line Leak Detector Model: <br /> ❑Tank Overfill/High-level Sensor: Model: ❑Tank Overfill/High-level Sensor: Model: <br /> ❑Other, Specify equip.type and model in Section E on Page 2 ❑Other,S ecif a ui .t e and model in Section E on Page 2 <br /> Dispenser ID: Dispenser ID: <br /> ❑Dispenser Containment Sensor(s): Model: ❑Dispenser Containment Sensor(s): Model: <br /> ❑ Shear Valve(s). ❑ Shear Valve(s). <br /> []Dispenser Containment Float(s)and Chain(s) ❑Dispenser Containment Float(s)and Chain(s) <br /> Dispenser ID: Dispenser ID: <br /> []Dispenser Containment Sensor(s): Model: ❑Dispenser Containment Sensor(s): Model: <br /> ❑ Shear Valve(s). ❑ Shear Valve(s). <br /> ❑Dis enser Containment Float(s)and Chain(s) ❑Dispenser Containment Float(s)and Chain(s) <br /> Dispenser ID: Dispenser ID: <br /> ❑Dispenser Containment Sensor(s): Model: ❑Dispenser Containment Sensor(s): Model: <br /> ❑ Shear Valve(s). ❑ Shear Valve(s). <br /> ❑Dis enser Containment Float(s)and Chain(s) ❑Dis enser Containment Float(s)and Chain(s) <br /> *If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification - 1 certify that the equipment identified in this document was inspected/serviced in accordance with the <br /> manufacturers' guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that <br /> this information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating <br /> such reports, I have also attached a copy of the report; (check all that apply): Z System set-up Z Alarm history <br /> report p--�1 <br /> Technician Name(Print): PHILIP FLUTY Signature: 1" fflA <br /> Certification No.: 1 1208 License No.: 588098 <br /> Testing Company Name: TAIT ENVIRONMENTAL SYSTEMS Phone No.: (714)560-8222 <br />
The URL can be used to link to this page
Your browser does not support the video tag.