AT&T California - UE020
STREET_NUMBER
124
Direction
W
STREET_NAME
ELM
STREET_TYPE
St
City
Lodi
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
124 W Elm St
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231866_124 W ELM_2001-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
312
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
8. F0 RISER CONTAINMENT SUMP TE§&G <br /> Tgst Method Developed By: ❑ Sump Manufacturer ®Industry Standard ®Professional Engineer <br /> ❑Other(Spec) <br /> Test Method Uses: ❑Pressure ❑Vacuum ®Hydrostatic <br /> ❑ Other(Specify) <br /> Measuring Equipment Used for Testing: Tempsonic 92 <br /> Fill Sump#1 Fill Sump# Fill Sump# <br /> Sump Diameter: 38" <br /> Sump Depth: 48" <br /> Height from Tank Top to N/A <br /> Highest Piping Penetration: <br /> Height from Tank Top to 16" <br /> Lowest Electrical Penetration: <br /> Condition of sump prior to OK <br /> testing: <br /> Portion of Sump Tested 9" <br /> Sump Material: FIBERGLASS <br /> Wait time between applying 10 MINUTES <br /> pressure/vacuum/water and <br /> starting test: <br /> Test Start Time: 10:00 10:15 <br /> Initial Reading(RI): 0.0000 0.0000 <br /> Test End Time: 10:15 10:30 <br /> Final Reading(RF): .0005 .0004 <br /> Test Duration: 15 MIN 15 MIN <br /> Change in Reading(RF-Ri): .0005 .0004 <br /> Pass/Fail Threshold: .002 .002 <br /> Test,Result• r :'F;" 3 PAS" <br /> Is there a sensor in the sump? YES <br /> Does the sensor alarm when N/A <br /> either product or water is <br /> detected? <br /> Was sensor removed for YES <br /> testing? <br /> Was sensor properly replaced YES <br /> after testing? <br /> Comments—(include information on repairs made to facilitate a passing test and indicate whether a <br /> permit was obtained for the repairs) <br /> R.C.U.S.T.COM <br />
The URL can be used to link to this page
Your browser does not support the video tag.