My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELM
>
124
>
2300 - Underground Storage Tank Program
>
PR0231866
>
COMPLIANCE INFO_2006-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/15/2020 4:02:36 PM
Creation date
6/3/2020 9:53:21 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2009
RECORD_ID
PR0231866
PE
2361
FACILITY_ID
FA0003957
FACILITY_NAME
AT&T California - UE020
STREET_NUMBER
124
Direction
W
STREET_NAME
ELM
STREET_TYPE
St
City
Lodi
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
124 W Elm St
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231866_124 W ELM_2006-2009.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
483
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
} 't <br /> Appendix VI <br /> (Copies of Monitoring System Certification form and LIST Monitoring Plot Plan available at http://www,waterboards.ca,gov) <br /> Monitoring System Certification <br /> For Use By All Jurisdictions Within the State of Califomia <br /> Authority Cited:Chapter 6.7,Health and Safety Code;Chapter 16,Division 3, Title 23,California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for each <br /> monitoring system control panel by the technician who performs the work.A copy of this form must be provided to the tank system owner/operator.The <br /> ownerloperator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> Facility: Pacific Bell Telephone Co.dba AT&T California GEO PAR#UE020 <br /> Address: 124 W. ELM ST. City: LODI Zi : 95242 <br /> Facili Contact Person: Connie Mitchell Contact Phone No:209-474-4022 <br /> Make/Model of Monitoring System:Veeder Root TLS-350 Service Date: 12/04/2009 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment Inspectedlserviced: <br /> Tank ID:UE020U001 Tank ID: <br /> ®In-Tank Gauging Probe Model:847390-107 ❑In-Tank Gauging Probe Model: <br /> ❑Annular Space or Vault Sensor Modek ❑Annular Space or Vault Sensor Model: <br /> ❑Piping Sump/Trench Sensor(s) Model: ❑Piping Sump/Trench Sensor(s) Model: <br /> ❑Fill Sump Sensor(s) Model: Q Fill Sump Sensor(s) Model: <br /> ❑Mechanical Line Leak Detector Model: ❑Mechanical Line Leak Detector Model: <br /> ❑Electronic Line Leak Detector Model: ❑Electronic Line Leak Detector Madel: <br /> ®Tank Overfill/High Level Sensor Model:790091-001 ❑Tank Overfill/High Level Sensor Model: <br /> ❑Other(Specify equipment type and model in Section E on Page 2) ❑OtherS eci <br /> ( p fy equipment type and model in Section E on Page 2) <br /> Tank ID: Tank ID: <br /> ❑In-Tank Gauging Probe Model: ❑In-Tank Gauging Probe Model: <br /> ❑Annular Space or Vault Sensor Model: ❑Annular Space or Vault Sensor Model: <br /> Q Piping Sump/Trench Sensor(s) Model: ❑Piping Sump/Trench Sensor(s) Model: <br /> ❑Fill Sump Sensor(s) Model: ❑Fill Sump Sensor(s) Model: <br /> ❑Mechanical Line Leak Detector Model: ❑Mechanical tine Leak Detector Model: <br /> ❑Electronic Line Leak Detector Model: ❑Electronic Line Leak Detector Model: <br /> ❑Tank Overfill/High Level Sensor Model: ❑Tank Overfill/High Level Sensor Model <br /> ❑Other(Specify equipment type and model in Section E on Page 2) ❑Other(Specify equipment p type and model in Section E on Page 2) <br /> Dispenser ID: Dispenser ID: <br /> ❑Dispenser Containment Sensor(s) Model: ❑Dispenser Containment Sensor(s) Model: <br /> ©Shear Valve(s) ❑Shear Vafve(s) <br /> ❑Dispenser Containment Float(s)and Chain(s) ❑Dispenser Containment Float(s)and Chain(s) <br /> Dispenser ID: DIsDenserID: <br /> ❑Dispenser Containment Sensor(s) Model: ❑Dispenser Containment Sensor(s) Model: <br /> ❑Shear Valve(s) Q Shear Valve(s) <br /> ❑Dispenser Containment Float(s)and Chain(s) ❑Dispenser Containment Float(s)and Chaln(s) <br /> DispenserlD: _Dispenser ID: <br /> ❑Dispenser Containment Sensors) Model: ❑Dispenser Containment Sensor(s) Model; <br /> ❑Shear Valve(s) ❑Shear Valve(s) <br /> ❑Dispenser Containment Float(s)and Chain(s) ❑Dispenser Containment Float(s)and Chain(s) <br /> If the facility contains more tanks or dispensers,copy this form.include information for every tank and dispenser at the facility. <br /> C. Certification-I certify that the equipment Identified In this document was Inspected/serviced In accordance with the <br /> manufacturers'guidelines.Attached to this Certification Is information(e.g.manufacturers'checklists)necessary to verify <br /> that this Information is correct and a Piot Plan showing the layout of monitoring equipment.For any equipment capable of <br /> generating such reports,I have also attached a copy of the report;(check all that apply): <br /> ®System set-up ®Alarm history report <br /> Technician Name(Print): John Cascio Si nature: <br /> Certification No: B35337 I License No 88098 <br /> Testing Company Name:TAIT ENVIRONMENTAL SERVICES -'✓ Phone No: 714 560-8222 <br /> Testing Company Address:2131 South Dupont Drive Anaheim CA 92806 1 Date of Testin Servicin : 12/04/2009 <br /> Monitoring System Certification Page 1 of 4 12/07 <br /> 1 2121/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.