My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELM
>
124
>
2300 - Underground Storage Tank Program
>
PR0231866
>
COMPLIANCE INFO_2006-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/15/2020 4:02:36 PM
Creation date
6/3/2020 9:53:21 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2009
RECORD_ID
PR0231866
PE
2361
FACILITY_ID
FA0003957
FACILITY_NAME
AT&T California - UE020
STREET_NUMBER
124
Direction
W
STREET_NAME
ELM
STREET_TYPE
St
City
Lodi
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
124 W Elm St
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231866_124 W ELM_2006-2009.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
483
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
t � <br /> MON14UNG SYSTEM CERTIFI TION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16,Division 3, Title 23, California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for each <br /> monitoring system control panel by the technician who perforn s the work A copy of this form must be provided to the tank system <br /> owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> Facility Name: PAC BELL dba AT&T CALIFORNIA Geo Par#: UE020 CLLC Code: LODICA01 <br /> Site Address: 124 W.ELM STREET City: LODI Zip: 95240 <br /> Facility Contact Person: CONNIE MITCHELL Contact Phone No.: (209)474-4022 <br /> Make/Model of Monitoring System: VEEDER ROOT TLS 350 PLUS Date of Testing/Service: 07/05/07 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate s ecific equipment ins ected/serviced: <br /> Tank ID: TANK# 1214 Tank ID: <br /> ®In-Tank Gauging Probe Model: 847390-107 ❑In-Tank Gauging Probe: Model: <br /> ®Annular Space or Vault Sensor: Model: 794390-420 ❑Annular Space or Vault Sensor Model: <br /> ®Piping Sump/Trench Sensor(s): Model: 794380-352 ❑Piping Sump/Trench Sensor(s): Model: <br /> Will Sump Sensor(s): Model: 794380-352 ❑Fill Sump Sensor(s): Model: <br /> []Mechanical Line Leak Detector. Model: N/A ❑Mechanical Line Leak Detector. Model: <br /> ❑Electronic Line Leak Detector Model: N/A ❑Electronic Line Leak Detector Model: <br /> []Tank Overfill/High-level Sensor: Model: 790091-001 ❑Tank Overfill/High-level Sensor: Model: <br /> ®Other, Specify equip.type and model in Section E on Page 2 ❑Other,Specify equip.type and model in Section E on Page 2 <br /> Tank ID: Tank ID: <br /> ❑In-Tank Gauging Probe: Model: ❑In-Tank Gauging Probe: Model: <br /> []Annular Space or Vault Sensor: Model: ❑Annular Space or Vault Sensor Model: <br /> ❑Piping Sump/Trench Sensor(s): Model: ❑Piping Sump/Trench Sensor(s): Model: _ <br /> ❑Fill Sump Sensor(s): Model: []Fill Sump Sensor(s): Model: <br /> ❑Mechanical Line Leak Detector. Model: ❑Mechanical Line Leak Detector. Model: <br /> []Electronic Line Leak Detector Model: ❑Electronic Line Leak Detector Model: <br /> ❑Tank Overfill/High-level Sensor: Model: ❑Tank Overfill/High-level Sensor: Model: <br /> ❑Other, Specify equip. a and model in Section E on Page 2 []Other, Specify equip. e and model in Section E on Page 2 <br /> Dispenser ID: Dispenser ID: <br /> ❑Dispenser Containment Sensor(s): Model: ❑Dispenser Containment Sensor(s): Model: <br /> ❑ Shear Valve(s). ❑ Shear Valve(s). <br /> ❑Dis enser Containment Float(s)and Chain(s) ❑Dis enser Containment Float(s)and Chain(s) <br /> Dispenser ID: Dispenser ID: <br /> ❑Dispenser Containment Sensor(s): Model: ❑Dispenser Containment Sensor(s): Model: <br /> ❑ Shear Valve(s). ❑ Shear Valve(s). <br /> ❑Dis enser Containment Floats and Chain(s) ❑Dispenser Containment Float(s)and Chain(s) <br /> Dispenser ID: Dispenser ID: <br /> ❑Dispenser Containment Sensor(s): Model: ❑Dispenser Containment Sensor(s): Model: <br /> ❑ Shear Valve(s). ❑ Shear Valve(s). <br /> ❑Dis enser Containment Float(s)and Chain(s) ❑Dis enser Containment Float(s)and Chain(s) <br /> *If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the <br /> manufacturers' guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that <br /> this information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating <br /> such reports, I have also attached a copy of the report; (check all that apply): ❑x System set-up ❑x Alarm history <br /> report <br /> Technician Name(Print): MICHAEL STRAWN Signature: _ �� <br /> Certification No.: A31215 License No.: 588098 <br /> Testing Company Name: TAIT ENVIRONMENTAL SERVICES Phone No.: (714)560-8222 <br />
The URL can be used to link to this page
Your browser does not support the video tag.