My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELM
>
124
>
2300 - Underground Storage Tank Program
>
PR0231866
>
COMPLIANCE INFO_2006-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/15/2020 4:02:36 PM
Creation date
6/3/2020 9:53:21 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2009
RECORD_ID
PR0231866
PE
2361
FACILITY_ID
FA0003957
FACILITY_NAME
AT&T California - UE020
STREET_NUMBER
124
Direction
W
STREET_NAME
ELM
STREET_TYPE
St
City
Lodi
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
124 W Elm St
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231866_124 W ELM_2006-2009.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
483
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
v 1Yj„ <br />MONIAUNG SYSTEM CERTIFICATION <br />For Use By All Jurisdictions Within the State of California��. <br />Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regula��� <br />6' <br />This form must be used to document testing and servicing of monitoring equipment. A separate <br />certification or report must be prepared for each monitoring system control panel by the technician <br />who performs the work. A copy of this form must be provided to the tank system owner/operator. The <br />owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 <br />days of test date. A. General Information <br />Facility Name: AT&T/SBC GEO PAR # UE -020 <br />Site Address: 124 W. ELM STREET <br />Facility Contact Person: <br />TOM WILLIAMS <br />City: LODI <br />CLLC Code: LODICA01 <br />Zip: <br />Contact Phone No.: 209-466-1010 <br />Make/Model of Monitoring System: VEEDER-ROOT TLS -350 PLUS <br />B. Inventory of Equipment Tested/Certified <br />Check the appropriate boxes to indicatespecific equipment inspected/serviced: <br />Date of Testing/Service: 7/19/06 <br />Tank ID: 1214 <br />Tank ID: <br />ZIn-Tank Gauging Probe: <br />Model: 847390- <br />❑In -Tank Gauging Probe: <br />Model: <br />®Annular Space or Vault Sensor: <br />Model: 794390-420 <br />❑Annular Space or Vault Sensor <br />Model: <br />®Piping Sump/Trench Sensor (s): <br />Model: 794380-352 <br />[]Piping Sump/Trench Sensor (s): <br />Model: <br />®Fill Sump Sensor (s): <br />Model: 794380-352 <br />❑Fill Sump Sensor (s): <br />Model: <br />❑Mechanical Line Leak Detector. <br />Model: <br />❑Mechanical Line Leak Detector. <br />Model: <br />[]Electronic Line Leak Detector <br />Model: <br />❑Electronic Line Leak Detector <br />Model: <br />®Tank OverfilUHigh-level Sensor: <br />Model: 790991-001 <br />❑Tank Overfill/High-level Sensor: <br />Model: <br />®Other, Specify a ui . e and model in Section E on Pae 2 <br />❑Other, Specify equip. e and model in Section E on Pa e 2 <br />Tank ID: <br />Tank ID: <br />❑In -Tank Gauging Probe: <br />Model: <br />❑In -Tank Gauging Probe: <br />Model: <br />❑Annular Space or Vault Sensor: <br />Model: <br />❑Annular Space or Vault Sensor <br />Model: <br />❑Piping Sump/Trench Sensor (s): <br />Model: <br />[]Piping Sump/Trench Sensor (s): <br />Model: <br />❑Fill Sump Sensor (s): <br />Model: <br />❑Fill Sump Sensor (s): <br />Model: <br />❑Mechanical Line Leak Detector. <br />Model: <br />❑Mechanical Line Leak Detector. <br />Model: <br />❑Electronic Line Leak Detector <br />Model: <br />❑Electronic Line Leak Detector <br />Model: <br />❑Tank Overfill/High-level Sensor: <br />Model: <br />❑Tank Overfill/High-level Sensor: <br />Model: <br />❑Other, Specify equip. e and model in Section E on Pa e 2 <br />❑Other, Specify equip. e and model <br />in Section E on Pa e 2 <br />Dispenser ID: <br />Dispenser ID: <br />❑Dispenser Containment Sensor(s): <br />Model: <br />❑Dispenser Containment Sensor(s): <br />Model: <br />❑ Shear Valve(s). <br />❑ Shear Valve(s). <br />❑Dis enser Containment Float(s and Chain(s) <br />[]Dispenser Containment Float(s) and Chain(s) <br />Dispenser ID: <br />Dispenser ID: <br />❑Dispenser Containment Sensor(s): <br />Model: <br />❑Dispenser Containment Sensor(s): <br />Model: <br />❑ Shear Valve(s). <br />❑ Shear Valve(s). <br />❑Dis enser Containment Float(s) and Chain(s) <br />❑Dis enser Containment Float(s) and Chain(s) <br />Dispenser ID: <br />Dispenser ID: <br />❑Dispenser Containment Sensor(s): <br />Model: <br />❑Dispenser Containment Sensor(s): <br />Model: <br />❑ Shear Valve(s). <br />❑ Shear Valve(s). <br />❑Dis enser Containment Floats and Chain(s) <br />❑Dis enser Containment Float(s) and Chains <br />*If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. <br />C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the <br />manufacturers' guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that <br />this information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment ca 3able of generating <br />such reports, I have also attached a copy of the report; (check all that apply): Z System t -u Z Alarm i <br />report <br />Technician Name (Print): MICHAEL L. STRAWN, II Signature: <br />Certification No.: 006-05-3018 License No.: 58809 <br />
The URL can be used to link to this page
Your browser does not support the video tag.