EQXX.MH11766 - Control, Monitorin d Auxiliary Equipment Page 4 of 5
<br /> Overfill Alarm Form No. 790091-00 with or without an Acknowledgement Switch Form No. 790095-001;
<br /> Remote Display Unit, Form No. 8478,followed by 8 or 9,followed by 0, followed by 1 or 2,followed by 1 or 2, followed by 1 or 2. Form No. 847090-
<br /> 1 followed by 0, 1 or 2, followed by 2;
<br /> The control unit may be provided with a combination of Plug-in Modules Form Nos. 847490-001, 100, -101, -102, -103, -104, -105, -106, -109, -
<br /> 110, -111, -202, -204, -206, -207, -208, -209, -210, -300, -301, 302, -303, -304, -305, -306, -309, -315, -316, -317, -326, -327, -340, -350, 360, -
<br /> 370, -380, -400, -401, -410, -420, -430, -431, 480 or Form No. 329359-001, 329360-001, 332250-001 (only one can be provided), or 332451-001.
<br /> Form No. 847090-1, control unit may additionally be provided with Form No. 847490 107 or-108 plug-in modules.
<br /> Advanced Application Module, Form No. 849090 followed by 5 or 8,followed by 00 to 16 inclusive and up to 16 liquid sensors; Form No. 7943
<br /> followed by 8 or 9, followed by 0,followed by-205, -301, 302, -401, -404,407, -409 or-420; TLS-RF Console, up to four may be connected to
<br /> intrinsically safe field wiring terminals but cannot be placed in the hazardous location.
<br /> May connect up to 64 of the intrinsically safe apparatus below.These devices have been evaluated for use in Class I, Division 1, Group D hazardous
<br /> locations when connected to the above in accordance with manual number 576013-879.
<br /> Magnetostrictive probes- Form No 1,followed by 0, 1, 2, 3, 4, 5,6 or 7, followed by 00 to 17 inclusive, 99, or Form No.
<br /> 84639 followed by 0 to 9, followed by 0 to 9,followed by 00 to 99;
<br /> Liquid or Vapor Sensors- Form No. 7943 followed by 9,followed by 0,followed by 0, 1 or 2, followed by 01 to 32, inclusive or Model 794390
<br /> followed by-321, -322, 340, -351, -352, -401, -404, -407, -409,420, -441,444, -447, -449 or-460 or-700, or Model 794380 followed by 208, -209,
<br /> -301, -302, -303, -304, -320, -321, -322, -323, -340, -341, -342, -343, -344, -350, -351, -352, -360, -361, -362, -363, -364, -430, -621, -622 or-
<br /> 624 or Form No. 857080-XXX or Form No. 181500 XXX, where XXX is any 3 digit number;
<br /> ISD Flow Meter- Form No. 331847-001, 331847-002, 332374-001 or 332374-002;
<br /> ISD Pressure Sensor- Form No. 330020-515 or 330020-630;
<br /> Volumetric Line Leak Detectors- up to eight Form Nos. 847590-001, -002, or-101;
<br /> Pressure Line Leak Detectors- Form Nos. 848480-001,002,003, -011, -012 or-013,
<br /> Vacuum Sensors- Form No. 857280-XXX;
<br /> Vacuum Sensor Assemblies-Form No. 330020-XXX, where XXX is any three digit number;
<br /> Pollulert System sensors Models 210, 210V, 221G, 221V, 241G, 241R, with prefix FD or MD and suffix RA, must be UL Listed.
<br /> 2 to 1 Sensor Input Box -Form No. 857390-102
<br /> Gilbarco Series Encore300, 350, 500 or 550 dispensers with Guardian option, must be UL Listed.
<br /> CCVP-Form No. 861290-XXX.
<br /> Last Updated on 2009-07-22
<br /> Questions? Notice of Disclaimer Page Top
<br /> Copyright n 2009 Underwriters Laboratories Inc
<br /> The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under
<br /> UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up Service. Always
<br /> look for the Mark on the product.
<br /> UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1.The Guide Information,
<br /> Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings).
<br /> 2.The statement"Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the
<br /> extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright© 2009 Underwriters
<br /> Laboratories Inc.@"
<br /> http://database.ul.com/cgi-bin/XYV/template/LISEXT/1 FRAME/showpage.html?name=EQXX.MH 117... 10/16/2009