My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELM
>
124
>
2300 - Underground Storage Tank Program
>
PR0231866
>
COMPLIANCE INFO_2010-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/15/2020 4:20:31 PM
Creation date
6/3/2020 9:53:27 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2018
RECORD_ID
PR0231866
PE
2361
FACILITY_ID
FA0003957
FACILITY_NAME
AT&T California - UE020
STREET_NUMBER
124
Direction
W
STREET_NAME
ELM
STREET_TYPE
St
City
Lodi
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
124 W Elm St
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231866_124 W ELM_2010-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
408
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 <br /> 4. TANK ANNULAR TESTING <br /> Test Method Developed By: ❑Tank Manufacturer El Industry Standard ❑Professional Engineer <br /> ❑Other(Specify) <br /> Test Method Used: ❑Pressure ®Vacuum ❑Hydrostatic <br /> ❑Other(Specify) <br /> Test Equipment Used: 4"dial guage Equipment Resolution: .1 <br /> UE0200001 <br /> Is Tank Exempt From Testing?' ❑Yes ®No ❑Yes ❑No ❑Yes El No ❑Yes ❑No <br /> Tank Capacity: 8,000 gallons <br /> Tank Material: Steel/fiberglass <br /> Tank Manufacturer: Modern Welding <br /> Product Stored: Diesel <br /> Wait time between applying <br /> pressure/vacuum/water and 15min <br /> starting test: <br /> Test Start Time: 9:57am <br /> Initial Reading(Ri): -10"hg <br /> Test End Time: 10:57am <br /> Final Reading(RF): -10"hg <br /> Test Duration: 1 hr <br /> Change in Reading(RF-RI): 0 <br /> Pass/Fail Threshold or Criteria: 0 <br /> Test Result: ®Pass ❑Fail ❑Pass ❑Fail ❑ Pass ❑Fail ❑ Pass ❑Fait <br /> Was sensor removed for testing? ®Yes ❑No ❑NA ❑Yes❑No❑NA ❑Yes❑No❑NA ❑Yes❑No❑NA <br /> Was sensor properly replaced and ❑Yes ❑X No ❑NA <br /> verified functional after testing? ❑Yes❑No❑NA ❑Yes❑No❑NA [--]Yes❑No❑NA <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> Sensor was removed but not tested, reinstalled to lowest point. <br /> R V E D <br /> L."' <br /> T <br /> t,' <br /> ")(, 2017 <br /> ENVIR NIN-4�ENTAL HEALTH <br /> ' Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br /> containment,such as systems that are hydrostatically monitored or under constant vacuum,are exempt from periodic containment <br /> testing. (California Code of Regulations,Title 23,Section 2637(a)(6)1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.