My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELM
>
124
>
2300 - Underground Storage Tank Program
>
PR0231866
>
COMPLIANCE INFO_2010-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/15/2020 4:20:31 PM
Creation date
6/3/2020 9:53:27 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2018
RECORD_ID
PR0231866
PE
2361
FACILITY_ID
FA0003957
FACILITY_NAME
AT&T California - UE020
STREET_NUMBER
124
Direction
W
STREET_NAME
ELM
STREET_TYPE
St
City
Lodi
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
124 W Elm St
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231866_124 W ELM_2010-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
408
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D. Results of Testing/Servicing 4RECEIVED <br /> Software Version Installed: 122.00 MAR 3 2017 <br /> Complete the following checklist: <br /> pi <br /> nMYe ❑No* Is the audible alarm operational? <br /> ❑No* Is the visual alarm operational? <br /> ❑No* Were all sensors visually inspected, functionally tested,and confirmed operational? <br /> ❑No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment <br /> will not interfere with their <br /> ro r o ration? <br /> ❑X Yes ❑No* If alarms are relayed to a remote monitoring station, is all communications equipment(e.g.modem) <br /> ❑N/A operational? <br /> ❑ Yes ❑No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary <br /> QN/A containment monitoring system detects a leak, fails to operate,or is electrically disconnected?If yes:which <br /> sensors initiate positive shut-down? (Check all that apply) <br /> ❑ Sump/Trench Sensors; ❑Dispenser Containment Sensors. Did you confirm positive shut-down <br /> due to leaks and sensor failure/disconnection? <br /> ❑Yes; ❑No. <br /> ❑ Yes ❑No* For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e. no <br /> mechanical overfill prevention valve is installed),is the overfill warning alarm visible and audible at the <br /> FXIN/A tank fill point(s)and operating properly?If so, at what percent of tank capacity does the alarm trigger? <br /> ❑Yes* ❑X No Was any monitoring equipment replaced?If yes,identify specific sensors,probes, or other equipment <br /> replaced and list the manufacturer name and model for all replacement parts in Section E,below. <br /> ❑Yes* No Was liquid found inside any secondary containment systems designed as dry systems. (Check all that <br /> apply) ❑Product; ❑Water.If yes,describe causes in Section E, below. <br /> Q Yes ❑No* Was monitoring system set-up reviewed to ensure proper settings?Attach set up reports,if applicable <br /> ® Yes [:],,,No* Is all monitoring equipment operational per manufacturer's specifications? <br /> *In Section E below,describe how and when these deficiencies were orwill be corrected. <br /> E. Comments: <br /> Other sensors from one: <br /> L4 gen floor 794380-208/N/A-Certified. <br /> L5 Fire box 794380-208/730237-Certified. <br /> There is an overfill valve installed in drop tube. <br />
The URL can be used to link to this page
Your browser does not support the video tag.