My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1985-1993
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SAN JOAQUIN
>
345
>
2300 - Underground Storage Tank Program
>
PR0231867
>
COMPLIANCE INFO_1985-1993
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2023 4:35:11 PM
Creation date
6/3/2020 9:53:32 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1985-1993
RECORD_ID
PR0231867
PE
2361
FACILITY_ID
FA0003959
FACILITY_NAME
AT&T CALIFORNIA - UE042
STREET_NUMBER
345
Direction
N
STREET_NAME
SAN JOAQUIN
STREET_TYPE
ST
City
STOCKTON
Zip
95202
CURRENT_STATUS
01
SITE_LOCATION
345 N SAN JOAQUIN ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231867_345 N SAN JOAQUIN_1985-1993.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
463
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UST SYSTEM PRINTSET INFORMATION 0 <br />1. Four complete sets of plans (To include specification sheets and/or equipment brochures if not on file). <br />2. Plans drawn to scale in non -erasable print.-' <br />i <br />3. Plot plan to show location and number of tanks. <br />4. Tank cross-sectional diagram included on prints submitted: <br />5. Detail of tank, piping system, excavation and cover! <br />6. Tank(s) and piping approved by a nationally rnized independent testing organization. [Title 23, Subchapter 16, <br />Article 3, Sec. 2631 (r) & 26351 e.® ec de <br />7. Verification of product compatibility with the tank(s), piping, monitoring ! <br />device(s), epoxy or silicone glues, etc. [Section 2635 (b) (2)1- <br />8. Manufacturer's written installation instructions for tank(s), piping, monitoring devices, etc. [Section 2635 (b) (5)) <br />9. Tightness Test (NFPA 30) is required on both primary (10) and secondary (20) containment systems before covering: <br />[Section 2635 (b) (6) & (7)) <br />10. Double waited tanks using pressure or vacuum testing to monitor the annular space. [Section 2635 (b) (7)1 <br />11. NFPA 329 "Precision Test" required upon completion of installation with tank in operating condition. Test results to <br />be submitted directly to PHS/END from the testing company or owner of facility. [Health & Safety Code, Division 20,, <br />Chapter 6.7, Section 25291 (g)] <br />12. TANK COWOSITION <br />TANK # # <br /># # # <br /># <br />CAPACITY 2 a0_0 <br />MANUFACTURER here ()J��(; <br />COMPOSITIONStlej61L� <br />MODEL !la <br />PRODUCT ICJe1 <br />CORROSION PROTECTION �i t �tl1j CO <br />Iri <br />U.L. LISTED Ye j <br />COMPATIBILITY WITH 100% W <br />METHANOL l -C, <br />13. TANK(s) TO BE INSTALLED <br />A. Steel -clad with fiberglass reinforced plastic. <br />B. Holiday test required immediately before "setting1° tank(s) (35,000 - 40,000 volts). [Section 2635 (b) (4)l <br />C. Fiberglass [Sections 2635 (3) and 2631 (p)) <br />_, (1) Striker plate dimensions and materials. <br />(2) Striker plate under all accessible openings. <br />(3) Installation instructions require an air test and soap bubble test prior to installation. <br />I-JIN D. Non -clad steel tank [Section 2635 (b)l <br />(1) Cathodic protection provided for entire tank, piping and components (rests, bolts, washers, <br />etc.). <br />(2) Approved by a corrosion engineer or N.A.C.E. technician. <br />(3) Document stating inspection method and frequency (minimum semi-anduat inspection requirement). <br />4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.