Laserfiche WebLink
A911L <br /> San Joaquin County 1W <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax:(209)468-3433 Web:www.s*gov.orQ/ehd <br /> �T <br /> de ­ 6f ,nd <br /> Inspc [o <br /> n <br /> Report <br /> Facility Name: Facility Phone: Date: <br /> AT&T CALIFORNIA- UE042 (209) 603-9726 July 11, 2018 <br /> Facility Address: CERS ID: <br /> 345 N SAN JOAQUIN ST, STOCKTON, CA 95202 10198666 <br /> Inspection Contact: Title: Phone: <br /> Dave Dube Environmental Site Mgr. (209) 532-3447 <br /> Inspection Type: Program: <br /> ROUTINE INSPECTION -Operating Permit 2361 - LIST FACILITY <br /> Consent For: I Consent Given By: <br /> M Inspection Z Photos Z Sample I Dave Dube, Environmental Site Manager <br /> Service Technician Onsite: Exp.Date: 'Designated Operator: Exp.Date: <br /> Jerry Sanouvong 03/23/2020 George Koffel 10/27/2018 <br /> Service Technician Manufacturer's Training <br /> Veeder-Root, 03/26/19 <br /> U(;K California Code of Regulations HSC Health and Safety Code CFR Code of Federal Regulations <br /> V=Violation R=Repeat violation COS=Corrected on site during inspection <br /> 'T 'j <br /> 101 HSC 25284 Failure to obtain a valid permit to operate from the EHD including but not limited to unpaid fees o V o R o COS <br /> 102 HSC 25284(a)(3)(A)/(B) No written agreement between tank owner and tank operator to monitor the tank system o V o R o COS <br /> 103 HSC 25292.2,25299.30 Current financial responsibility documents not submitted o V o R o COS <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current Ei V Li R o COS <br /> 105 CCR 2632(d)(1), Failed to have an approved UST monitoring plan Ei V o R o COS <br /> 12634(d) <br /> 106 CCR 2632(d)(2), Failed to have an approved UST response plan o V o R o COS <br /> 2634(e) <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed o V D R o COS <br /> 108 CCR 2637ft 2638(e) Failed to notify the EHD 48 hours prior to conducting testing Ei V o R o COS <br /> 109 CCR 2637 Failed to test secondary containment Ei V o R o COS <br /> 110 CCR 2637(e) Failed to submit secondary containment test report within 30 days E:i V o R o COS <br /> 111 CCR 2638(a) Failed to test monitoring and leak detection equipment annually o V o R Ei COS <br /> 112 HSC 25284.2 Failed to test spill containers annually Li V o R o COS <br /> 113 CCR 2638(d) Failed to submit monitoring system certification test report within 30 days Li V o R o COS <br /> 114 CCR 2636(f) Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down 0 V 11 R o COS <br /> 115 CCR 2715(a) Failed to submit to EHD notification of designated operator identification or change Win 30 days o V c R o COS <br /> 116 CCR 2715 Designated operator,service tech or installer did not possess current ICC certification Ei V Ei R o COS <br /> 117 CCR 2663(h) Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after ii V o R o COS <br /> 118 CCR 2663 Failed to submit tank lining certification within 30 days or to conduct proper tests o V o R o COS <br /> 119 HSC 25299(a)(8), Documents were falsified or misrepresented o V o R Ei COS <br /> 25299(b)(7) <br /> 120 CCR 2635(d) Failed to submit UST Certification of Installation/Modification c V Ei R Ei COS <br /> 121 CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report o V Ei R c COS <br /> 122 CCR 26310) Failure to submit and maintain UST system component statement of compatibility for substance stored ii V o R ii COS <br /> 'Fu <br /> Z <br /> M, <br /> i'd <br /> z4l� J�k <br /> 201 CCR 2712(b) Failure to maintain monitoring,maintenance,and follow up action records o V o R o COS <br /> 202 CCR 2712(b) Failed to maintain cathodic protection test records on site for at least 6 112 years Li V Ei R Ei COS <br /> FA0003959 PR0231867 SCO01 07/11/2018 <br /> EHD 23-01 Rev.09/22/16 Page 1 of 4 Underground Storage Tank Program OIR <br />