My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2004-2006
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
12TH
>
10
>
2300 - Underground Storage Tank Program
>
PR0231873
>
COMPLIANCE INFO_2004-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/9/2024 11:02:29 AM
Creation date
6/3/2020 9:53:57 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004-2006
RECORD_ID
PR0231873
PE
2361
FACILITY_ID
FA0003956
FACILITY_NAME
PACIFIC BELL - UE058 (TRACY)
STREET_NUMBER
10
Direction
E
STREET_NAME
12TH
STREET_TYPE
St
City
TRACY
Zip
95376
APN
23336922
CURRENT_STATUS
01
SITE_LOCATION
10 E 12TH St
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231873_10 E 12TH_2004-2006.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
351
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
California Edition:June 1999 <br /> Veeder-Root <br /> wn:�sw <br /> TLS-200/200i/250/250i/300/300c/300i/300pc/350/350pc/350r/350rpc UST ATGS <br /> (8473 Digital Sensing Magnetostrictive Probe) _ <br /> r <br /> AUTOMATIC TANK GAUGING SYSTEM <br /> Certification: Leak rate of 0.2 gph with PD=99%and PFA=0.1%- <br /> Leak Threshold: 0.093 gph.A system should not be declared tight if the test result indicates a loss or <br /> gain.that equals or exceeds this threshold. <br /> Applicability: Gasoline,diesel,aviation fuel,and solvents. _ <br /> Tank Capacity: Maximum of 15,000 gallons. <br /> Tank must be between 50 and 95%full. <br /> Waiting Time: Minimum of 8 hours, 18 minutes between delivery and testing. <br /> Minimum of 30 minutes between dispensing and testing. <br /> There must be no delivery during waiting time. <br /> Test Period: Minimum of 2 hours. <br /> Test data are acquired and recorded by the system's computer. <br /> Leak rate is calculated from the difference between the fust and last data collected. <br /> There must be no dispensing during test. <br /> Temperature: Average for product is determined by a minimum of 5 thermistors. <br /> / Water Sensor: Must be used to detect water ingress. <br /> !. Minimum detectable water level in the tank is 0.544 inch. <br /> Minimum detectable change in water level is 0.027 inch. <br /> Calibration: Thermistors and probe must be checked and calibrated in accordance with <br /> manufacturer's instructions. <br /> Comments: Not evaluated using manifold tank systems. <br /> Tests only portion of tank containing product. <br /> As product level is lowered,leak rate in a leaking tank decreases(due to <br /> lower head pressure). Consistent testing at low levels could allow a leak to remain <br /> undetected. <br /> EPA leak detection regulations require testing of the portion of the tank system which <br /> routinely contains product. <br /> California regulations require at least one test per month after <br /> routine product delivery or when the tank is filled to within 10% of <br /> the highest operating level during the previous month. <br /> Veeder-Root Evaluator:Midwest Research Institute <br /> 125 Powder Forest Dr. Tei: (816)753-7600 <br /> Simsbury,CT 06070-2003 <br /> Tel: (860)651-2700 Date of Evaluation: 05/14/93 <br /> Appearance on this list is not to be construed as an endorsement by any regulatory agency nor is it any guarantee of the performance of the <br /> method or equiprnent. Equipment should be installed and operated in accordance with all applicable laws and regulations. <br /> 314 <br />
The URL can be used to link to this page
Your browser does not support the video tag.