My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1998-2003
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1001
>
2300 - Underground Storage Tank Program
>
PR0231876
>
COMPLIANCE INFO_1998-2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/16/2023 11:23:59 AM
Creation date
6/3/2020 9:54:04 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998-2003
RECORD_ID
PR0231876
PE
2361
FACILITY_ID
FA0000421
FACILITY_NAME
DINO MART
STREET_NUMBER
1001
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
1001 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231876_1001 E YOSEMITE_1998-2003.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
516
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TECHNICAL SOPECIFICATIONS <br /> • Compatible with <br /> ...100% gasoline, methanol, and ethanol <br /> PIP ..Any combination of the above <br /> ...100% diesel <br /> ...Up to 15% MTBE <br /> ...Kerosene/jet A/JP 4 <br /> • Use with any line/pipe system up to 250 ml <br /> The `96 LD-2000 is the newest generation of the most advanced system of bleed back <br /> mechanical fine leak detectors available. For 1996, the LD-2000 becomes even • For use with any UL listed pumps: X h.p., 4 h.p., <br /> more versatile. One leak detector for virtually any submersible pump, fuel, or line! and 1i� h.p — 20-50 psi, volume to 90 GPM <br /> 3rfi <br /> • Certified to handle 10+ feet of head pressure <br /> MM <br /> A patented, internal, free-floating check valve positioned at the downstream end of • Combination line check/pressure relief, prevents <br /> the leak detector protects the leak detector against damage caused by hydraulic <br /> hammer (a rebounding pressure wave formed when the dispenser nozzle is drainback into the tank <br /> closed). The check valve also maintain line pressure, sufficient to allow dispensa- • Hardened 17-4 stainless steel metering pin <br /> tion of fuel immediately, providing that the downstream dispensing line has no and poppet <br /> Leak. • Unique upper cylinder piston functions without <br /> a pressure relief <br /> FEATURES <br /> • Tamper-proof bolts accommodate wire seal <br /> • One leak detector for any fuel: gasoline, diesel, alcohol ® to prevent tampering <br /> • For any pipeline system up to 250 ml. bleed back • For installation in any submersible pump with <br /> • One leak detector for Red Jacket, FE Petro, or Tokheim submersible pumps <br /> • Lowest profile leak detector available for those tight locations a 2 inch NPT port, or a 2 inch leak <br /> • Maintains pressure in the delivery line when no leak is present detector adaptor tee <br /> • Detects leaks even if substantial hydrostatic shock occurs in the dispensing • Leak detector is nickel-plated, schedule 40 <br /> fine <br /> • Reduces unscheduled pump maintenance due to check valve deterioration or cast iron construction <br /> functional element deterioration • MIL Spec. #R-83248 Fleurocarbon O-ring <br /> • Provides improved performance under extreme climactic conditions • UL listed and certified to meet EPA <br /> • Best performance warranty in the industry, 3 GPH at 10 psi for 24 months GPH @ 10 psi performance specifications <br /> after date of installation online systems up to 130 gallons <br /> • Overcomes problems caused by thermal contraction and line resiliency in <br /> larger delivery systems • Vent line must be unobstructed, leak-proof, <br /> and connected to an atmospheric port <br /> PERFORMANCE (e.g. tank head space) <br /> • The `96 LD-2000 exceeds the EPA regulations that require detection of a 3 • For a complete list of materials and <br /> GPH leak at 10 psi. Under conditions of thermal expansion or contraction, other specifications, please contact VMI. <br /> the `96 LD-2000 is capable of detecting a 3 GPH leak with a probability of • Can be installed in an position <br /> detection of 100% and a false alarm probability of 0%. y <br /> • Under neutral test conditions, the `96 LD-2000 detected leaks under 2 GPH. <br /> • From pump start-up, the average leak sensing time to full flow was less than <br /> 5 seconds for pipe lines with up to 250 ml bleed back. aT7'96 n Information <br /> • The `96 LD-2000 detected leaks in the pipe system up to 10' above the leak LD-2000 mechanism is fully guaranteed to see a leak of 3 GPH @ 10 psi <br /> detector. This test, called a "Head Pressure Reset Test," ensures that all for a period of 24 months after date of installation. Warranty card and <br /> buried pipe is protected. installation instructions included in packaging. <br /> i <br />
The URL can be used to link to this page
Your browser does not support the video tag.