Laserfiche WebLink
Quick STOP Mart 20 264569 p.6 <br /> U"ERGROUND STORAGE'TANK <br /> RESPONSE PLAN-PAGE 2 <br /> VI. REPORTING AND RECOPW KEEPING <br /> we will reporifrecoid any overfill,spaj,or unauthorized release frau a UST system as indicated in this plan. <br /> Reoordsble Releases: Ary unauthorized release from primary containment which the UST operator is able to clean teat d a and w9ddt d <br /> up within eight(8)hours atter the release was <br /> detected should reasonably Dave oes not escape from coarminrnent,does not increase the of fire or explosion,and does <br /> DO'cause any dnaeriotaUort of ondary cotttai rmeat,mast be recorded in the facillly�s Monitoring records. Monitoring records must include: <br /> > The UST operator's era;and telephone ntanber, <br /> > A list of the types,quan*ies,and conceoTaations of hazardous Substat rG <br /> > A description of the actions taken to control and clean up the release; <br /> > The method and location of dispesai of the released hazardous substances,and whefier a hazardous waste rtfenifest was or vrill be used; <br /> A A description ofactions taken to repair the UST and to prevent futare releases; <br /> > A description of the method used to reactivate interstitial monitoring after rep}acerncr►t or rejrtti<of Prirnaty GDmaltitt=t <br /> Reportable Itekaaea: Any overfill,spill,or uniarthorized release whkh escapes frim secondary containment(or primary caontainrtient if nosecondary containment <br /> atists},increases the h%wd of fire or expstosion,Or causes any deterioration of secondary containment is a reportable release Reportable releases arc also recordable. <br /> Within 24 hours after a peparngbic release has been detect,or should have been detected,we will notify die local agency administering the UST program of the <br /> release,investVte the release,and bJw inarrediale measures to stop the release. If ,or if rewired by local agency, stored productivraste willbe removed from UST to prevent further releases or facilitate corrective actio, [fan emergency exists,%e wipl notify the State Of via of EumBency Services. <br /> Within five(5)working days of a reportable release,we will submit to the kcal agency a full written repot containing all of the foAowing iuf to the extent <br /> #0 the information is knovm at the time of filing dte report: <br /> > The UST--fte's or operators name and Wkphone narn ber, <br /> a A list of the types.quantifies,and concentrations of bxrardous materials released; <br /> > The approximate date of the release; <br /> > The date ori which the release was discovered; <br /> P The date on which the rekase was sopped; <br /> > A description of actions taken to control and(or stop the release: <br /> > A description of swrrei%ve and remedial actions,including investigations which were u dertalren and will be conducted to determine the nature azul=dent of <br /> s00,ground water or surface;water contamination due to the release; <br /> > The mcdtod(s)of cleanup imply nested to date,proposed cleanup actions,and a seliedule for imp the proposed actions; <br /> > The tnethod(s)aril location(s)ofdisposal of released hazardous materials and any contaminated Bala,grcundveaw,or surface ware. <br /> > Copies of any hazudous Waste manifests used for off-site ofhazardous wastes associ with clean-up activity; <br /> > A description ofproposed methods for any repairorrepiacement ofuw system primary/secondary containment systems; <br /> > A description ofadditionat actiais takcrn to prevent future releases. <br /> We will follow the reporting procedures described above if arty of the following conditions oxtu: <br /> > A recordable anemhorized release can net are cleaned up or is still under. atiat within sight(a)hours of detection; <br /> a Releasedd hazardous subaftlim are discaveted at the UST site or in the surrounding area; <br /> a <br /> Unusual operating conditions—observed,including tic sudden Whavier of product disc—ing equip—r,sun loss o or the presence of <br /> the Milk-less system equipment is found to be defective and is imineftely repaired or replaced,and no leak has ccunrt <br /> > Monitoring resukte from LIST system Monitoring equip menUmelhods indicate that a release may have occurred,unless the,monitoring equipment m you,xt a bedefective and is immediately repaired,recali6rateck or replaced,and additional mor itaing does not confirm the initial results. <br /> 1—rd Retention: Monwring records and tot IMM rep"of un"Mod relean mug be Maintained on-site(or offsite at a headily availalk location,if aWa ed <br /> by the kcal agency)for at least 3 gears. Hazardous wase shiprpirrg/diposal records(e.g.,mmnftts)must be maintained for at kart 3 years from tlhe date of shipment <br /> V11- OWNEWOPERATOR SIGNATURE <br /> CERT[FICATI IN:ICerfirythat the iuhrmulfto provided bereia is true sW accatrate to the best of my knowledge. <br /> U TOR SIGNA <br /> DATE unit <br /> Mj <br /> OWNS OPERATORNAME( Rtt. QWNMM MILE >rrz <br /> U <br /> (Agency Use 6i ) This plan has n reviewed and: PrAPprovod ®Approved With Conditions ❑Disapproved <br /> 4ocal Agency Sitpraturc:_ /� Date: 3 a/ .3 <br /> USC Restraiam Phis -313 <br />