Laserfiche WebLink
0 0 <br />SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax. (209) 468-3433 Web: www.sigov.or-q/ehd <br />Facility Facility inspection <br />Name: Bank of Stockton Address: 1941 Lockheed Court, Stockton I Date: Oct 15, 2013 <br />VIOLATIONS <br />jC1 <br />IC21 <br />M I <br />Code Section <br />HSC = CA Health and Safety Code; CFR = Code of Federal Regulations <br />C1 =,Class 1 violation; C2 = Class 2 violation; M = Minor violation <br />0011110 s (continued) <br />204 CCR 2715(c) Designated operator monthly inspection: (1) alarms not documented; (2-4) spill containers, UDCs, and sumps <br />if necessary) not inspected; (5) required test dates not checked or noted; (6) employee training not verified <br />205 CCR 2715(e) Designated operator monthly inspection reports not maintained on site for at least 12 months <br />206 CCR 2715(f) Designated operator employee training: (1) not performed; (2) not current for at least one employee on site; <br />(3) log not kept <br />—20_7 HSC 25281.5(b)(2) Unburied fuel piping at marinas not visually inspected at least daily or log not kept <br />301 HSC 25292.1 UST system is not operated to prevent unauthorized release, including spills and overfills <br />302 HSC 25291(b) UST monitoring system incapable of detecting leak from primary containment into secondary containment(mi) <br />303 CCR 2630(d) UST monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity (MI) <br />3134 CCR 2632(c)(2) Monitoring system is not present in the interstitial space of a double walled UST (Mi) <br />305 CCR 2636(%1) Failed to maintain a continuous monitoring system for underground piping & UDCs that activates an (MI) <br />audible and visual alarm or stops flow of product at the dispenser when it detects a leak <br />306 CCR 2631(a) Primary containment is not product tight <br />307 HSC 25291(a)(2) Secondary containment for UST system is not fight <br />308 CCR 2636(c)(1) All releases in secondary piping do not flow to a collection sump <br />309 CCR 2636(a) Failed to have secondary containment for piping (indudes conventional suction piping) (111112) <br />310 HSC 25291(e) Water in 21 containment not removed, analyzed & properly disposed of <br />311 CCR 2636(f)(2) Line leak detector(s) not installed or failed to detect a 3 -gallon per hour leak at 10 psi (MI) <br />312 CCR 2635(b) No spill container or overfill prevention system installed (M2) <br />Spill container failed to contain a minimum capacity of five gallons, or failed to provide a means to keep (1111112) <br />313 CCR 2635(b)(1) the spill container empty <br />314 CCR 2635(b)(2) Overfill prevention system was overridden or failed to meet overfill requirements (M2) <br />315 HSC 25299(f)(2) Tampering with or disabling leak detection devices or alarms <br />316 CCR 2631.1(a) UST system is not compatible with the substance stored <br />317 HSC 25298(a) Illegally abandoned UST system <br />AS 1702 (203-2004) HSC 2MO.2 (i lied bobveen 07101103 and ,06MOM4): <br />401 <br />Compatibility and permeability requirements: (a) UST system is not compatible with the substance stored; (b) <br />CCR 2631.1 results of the compatibility and permeability testing requirements listed in subsections CCR 2631(b) and (d) <br />for a UST system installed after July 1, 2004, were not submitted <br />402 <br />HSC 25290.1(c)(1) Primary containment not liquid or vapor tight <br />HSC 25290.2(c)(1) <br />403 <br />HSC 25290.1(c)(2) Secondary containment not liquid or vapor tight <br />HSC 25290.2(c)(2) <br />404 <br />HSC 25290.1(c)(3) Secondary containment not constructed to prevent water intrusion <br />HSC 25290.2(c)(3) <br />405 <br />HSC 25290.1(d) Monitoring system not maintained to detect water intrusion into the secondary containment, or the entry of <br />HSC 25290.2(d) liquid or vapor from the primary containment into the secondary containment <br />406 <br />HSC 25290.1(e) Interstitial liquid measurement method, constant vacuum, or constant pressure in the interstitial space of the <br />UST system not maintained <br />407 <br />HSC 25290.10) UST system not tested by one of the following methods prior to use: (1) Enhanced leak detection; (2) inert gas <br />pressure test approved by SWRCB; (3) test method deemed e uivalent to 1or 2bthe SWIRCB <br />HSC 25290.2 _q () () y <br />501 <br />CCR 2636(f)(6) Emergency generator monitoring system not checked daily or log not kept if no leak detector (MI) <br />502 1 j <br />HSC 25281-5(b)(3) Unburied fuel piping not visually inspected at least monthly or I og not kept (MI) <br />USTS 10*V40 <br />601 HSC 25283.5(a)(1) All exterior surfaces of the tank and connected piping cannot be directly viewed <br />602 HSC 25283.5(a)(2) Structure that the UST is located in does not provide for secondary containment <br />603 HSC 25283.5(a)(3) Failed to conduct weekly UST inspections or maintain a log of weekly inspections <br />604 HSC 25283.5(a)(5) UST installed after July 1, 2003, does not meet or exceed applicable sections of HSC 25291 <br />14010 urtWd Piping <br />701 CCR 2643(d) Daily monitoring of suction piping (pre -January 1, 1984) not performed (MI) <br />EHD23-02 Rev 04/22/13 Page 2 UST INSPECTION REPORT <br />Ali <br />EHD23-02 Rev 04/22/13 Page 2 UST INSPECTION REPORT <br />