COMPLIANCE INFO_1998-2004
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
2375
>
2300 - Underground Storage Tank Program
>
PR0231897
>
COMPLIANCE INFO_1998-2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/15/2024 1:45:39 PM
Creation date
6/3/2020 9:54:21 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998-2004
RECORD_ID
PR0231897
PE
2361
FACILITY_ID
FA0006443
FACILITY_NAME
Tracy Texaco
STREET_NUMBER
2375
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
23207003
CURRENT_STATUS
01
SITE_LOCATION
2375 N TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231897_2375 N TRACY_1998-2004.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
373
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UCSB04N—SS#2611194 Page 4 of 7 <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By: ❑ Sump Manufacturer N Industry Standard ❑Professional Engineer <br /> ❑ Other(Spec) <br /> Test Method Used: ❑Pressure ❑Vacuum N Hydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used: INCON TS-STS TEST UNIT Equipment Resolution: <br /> Sump#87 Sump#89 Sump#91 Sump# <br /> Sump Diameter: 48" 48" 48" <br /> Sump Depth: 44" 291/2'9 341/2" <br /> Sump Material: FIBERGLASS FIBERGLASS FIBERGLASS <br /> Height from Tank Top to Top of 18" 17" 18" <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest <br /> Electrical Penetration: 30" 26" 28" <br /> Condition of sump prior to testing: GOOD GOOD GOOD <br /> Portion of Sump Tested' 2"ABOVE HIGHEST 2"ABOVE HIGHEST 2"ABOVE HIGHEST <br /> PIPING PENETRATION PIPING PENETRATION PIPING PENETRATION <br /> Does turbine shut down when <br /> sump sensor detects liquid(both N Yes ❑No ❑NA N Yes ❑No ❑NA ®Yes ❑No [INA ❑Yes ❑No ❑NA <br /> product and water)?* <br /> Turbine shutdown response time NA NA N/A <br /> Is system programmed for fail-safe N Yes ❑No ❑NA N Yes ❑No ❑NA N Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> shutdown?" <br /> Was fail-safe verified to be ❑Yes NNo ❑NA ❑Yes NNo ❑NA ❑Yes N No ❑NA ❑Yes ❑No ❑NA <br /> operational?* <br /> Wait time between applying <br /> pressure/vacuum/water and starting 15 MINUTES 15 MINUTES 15 MINUTES <br /> test: <br /> Test Start Time: NA NA 12:01 12:17 NA NA <br /> Initial Reading(RI): NA NA 7.176 6.231 NA NA <br /> Test End Time: NA NA 12:16 12:32 NA NA <br /> Final Reading(RF): NA NA 6.344 5.693 NA NA <br /> Test Duration: NA NA 15 MIN 15 MIN NA NA <br /> Change in Reading(RF-R,): NA NA -0.832 -0.538 NA NA <br /> Pass/Fail Threshold or Criteria: -0.002 -0.002 -0.002 -0.002 -0.002 -0.002 <br /> Test Result: ❑ Pass ❑Fail ❑ Pass' N Fail ❑ Pass ❑Fail ❑ Pass ❑Fail, <br /> Was sensor removed for testing? N Yes ❑No ❑NA N Yes ❑No ❑NA N Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> Was sensor properly replaced and N Yes ❑No ❑NA N Yes ❑No ❑NA ®Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> verified functional after testing? <br /> Comments— (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> BOTH 87 AND 91 SUMPS COULD NOT BE TESTED DUE TO BAD SECONDARY BOOTS. <br />