ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005-2008
RECORD_ID
PR0231897
PE
2361
FACILITY_ID
FA0006443
FACILITY_NAME
Tracy Texaco
STREET_NUMBER
2375
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
23207003
CURRENT_STATUS
01
SITE_LOCATION
2375 N TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231897_2375 N TRACY_2005-2008.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
381
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Jun 20 06 10:05p Mike Dotten 209-533-2650 p.2 <br /> Facility: Tracy BP Service Center <br /> D. Results of Testing/Servicing <br /> Software Version Installed:Not Noted <br /> Com lets the following checklist: <br /> ®Yes ❑No* Is the audible alarm operational? ❑Outside Audible Alarm? <br /> Yes ❑No* is the visual alarm operational? <br /> Q{Yes ❑No* Is the print-function operational? 0 Not installed. <br /> Yes ❑No* Were all sensors visually inspected,functionally tested,and confirmed o erational? <br /> Yes ❑No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br /> not interfere with their proper operation? <br /> ❑Yes ❑ No* If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) <br /> ® N/A operational? <br /> ®Yes ❑ No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br /> ❑ N/A monitoring system detects a leak, fails to operate,or is electrically disconnected? If yes: which sensors initiate <br /> positive shut-down? (Check all that apply) ® Sump Sensors; Z Dispenser Containment Sensors. <br /> Did you confirm 2ositive shut-down due to leaks and sensor failure/disconnection? M Yes; ❑No. <br /> ❑Yes ❑ No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br /> ® N/A mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br /> fill oint(s)and operating ro erl ? If so,at what percent of tank ca i does the alarm trigger? <br /> ❑Yes* ®No Was any monitoring equipment replaced? If yes, identify specific sensors,probes,or other equipment replaced <br /> and list the manufacturer name and model for all replacement in Section E,below. <br /> ❑Yes* ®No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br /> ❑Product; ❑ Water. If yes,describe causes in Section E,below. <br /> ®Yes ❑No* Was monitoring system set-a reviewed to ensure Prom settin ?Attach set 2p reports,if applicable <br /> ® Yes ❑ No* Is all monito a ui mentoperational per manufacturer's specifications? <br /> *in Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments:No Deficiencies. <br /> Page 2 of 3 03101 <br />