Laserfiche WebLink
ti <br /> ENVIRO#VIENTAL HEALTH%EPARTMENT <br /> SAN JOAQUIN COUNTY <br /> 2 y Donna K. Heran, R.E.H.S. Unit Supervisors <br /> f`, :< Director 304 East Weber Avenue,Third Floor Carl Borgman,R.E.H.S. <br /> Laurie A. Cotulla, R.E.H.S. Stockton,California 95202-2708 Mike Huggins, R.E.H.S., R.D.I. <br /> Program Manager Douglas W. Wilson, R.E.H.S. <br /> Telephone: (209)468-3420 <br /> CqC%FpFt�\P Margaret Lagorio,R.E.H.S. <br /> Fax: (209) 464-0138 Robert McClellon, R.E.H.S. <br /> April 14,2006 Website:www.sjgov.org/ehd/ .teff Carruesco, R.E.H.S. <br /> JASON T MUSIAL <br /> TAIT ENVIRONMENTAL SERVICES <br /> 4280 TRADE CENTER DRIVE <br /> RANCHO CORDOVA, CA 95742 <br /> FAX: (916) 858-1011 <br /> Re: 2375 Tracy Blvd <br /> Tracy, CA <br /> Your application for a permit to repair the 89 STP sump and to break concrete and retrofit the <br /> piping associated with the under dispenser containments 3/4, 5/6, and 7/8 at the above referenced <br /> address has been received and approved with the following conditions: <br /> Conditions of approval: <br /> 1. Contact the fire department and San Joaquin Valley Air District for any applicable <br /> permits. <br /> 2. Any changes shall be submitted to EHD for approval prior to commencing work. All new <br /> addendums supercede the previous ones. <br /> 3. All piping and fittings must be certified by an independent testing organization and <br /> labeled as required by the organization. (UL,ULC, ANSI, API, ASTM, etc. See Title 23 <br /> Chapter 16 Table B for complete list) <br /> 4. At least one person who is certified as an ICC UST Installer/Retrofitter and manufacturer <br /> certified for all components worked on must be onsite at all times when work is <br /> performed on any portion of the UST System. <br /> 5. Contact EHD for the following inspections(Allow a 48 hour notice for all inspections): <br /> a. Primary piping soap test <br /> b. Secondary piping soap test <br /> c. 24 hour or equivalent lake test on UDCs and 89 STP sump. <br /> 6. Once concrete is poured all lines shall have an integrity test performed in accordance to <br /> manufacturer. Results must be received by EHD within 7 days of returning the site to <br /> operating condition. <br /> 7. If concrete is broken near the underground storage tanks they must be have an integrity <br /> test performed once concrete is poured in accordance to manufacture guidelines. Results <br /> must be received by EHD within 7 days of returning the site to operating condition. <br /> 8. This permit expires on June 30, 2006. <br /> To schedule an inspection, or if you have any questions,please contact me at(209)468-3448. <br /> Willy Ng,REHS <br /> Senior Registered Environmental Health Specialist <br />