COMPLIANCE INFO_JULY 2012-OCTOBER 2013
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
2375
>
2300 - Underground Storage Tank Program
>
PR0231897
>
COMPLIANCE INFO_JULY 2012-OCTOBER 2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2024 1:51:29 PM
Creation date
6/3/2020 9:54:51 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
JULY 2012-OCTOBER 2013
RECORD_ID
PR0231897
PE
2361
FACILITY_ID
FA0006443
FACILITY_NAME
Tracy Texaco
STREET_NUMBER
2375
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
23207003
CURRENT_STATUS
01
SITE_LOCATION
2375 N TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231897_2375 N TRACY_JULY 2012-OCTOBER 2013.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
491
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FLAMMABLE AND COMBUSTIBLE LIQUIDS <br /> nection secure against tampering. Vent lines shall 3404.2.13.2.2 Out of service for 90 days. <br /> remain open and be maintained in accordance with Above-ground tanks not used for a period of 90 days <br /> Sections 3404.2.7.3 and 3404.2.7.4. shall be safeguarded in accordance with Section <br /> 3404.2.13,1.2 or removed in accordance with Section <br /> 3404.2.13.1.2 Otit'of selvice for 90°:;days. Under- 3404.2,14. <br /> ground tanks not used for a period of 90 days shall be <br /> safeguarded in accordance with all the following•or be Exceptions: <br /> removed in accordance with Section 3404.2.14: 1. Tanks and containers connected to oil burn- <br /> 1. flammable or combustible liquids shall be re- ers that are not in use during the warm sea- <br /> moved from the tank. son of the year or are used as a backup <br /> 2. All piping,including fill line, gauge opening, heating system to gas. <br /> vapor return and pump connection, shall be 2. In-place, active fire protection(foam) sys- <br /> capped or plugged and secured from tampering. tem lines. <br /> 3. Vent lines shall remain open and be maintained 3404.2.13.2.3 Out of service for one year. <br /> in accordance with Sections 3404.2.7.3 and Above-ground tanks that have been out of service for <br /> 3404.2,7.4. a period of one year shall be removed in accordance <br /> ,3404.2.13.1.3 Out of service for one:year.Under- with Section 3404.2.14. <br /> ground tanks thathave been out of service for a period Exception:Tanks within operating facilities. <br /> of one year shall be removed from the ground inNJ 3404.2.14 Removal and disposal of tanks.Removal and <br /> place in c cords Section Sectio.14 0 abandoned in disposal of tanks shall comply with Sections 3404.2.14.1 <br /> place in accordance with Section 3404.2.13.1.4. and 3404.2.14.2, <br /> 3404.2.13.1.4..Tanks, abandoned in place. Tanks 3404.2.14.1 Removal. Removal of above-ground and <br /> abandoned iri place shall be as follows: underground tanks shall be in accordance with all of the <br /> `r 1. Flammable and combustible liquids shall be re- following: <br /> moved from the tank and connected piping, L Flammable and combustible liquids.,shall be re- <br /> 2. The suction,inlet,gauge,vapor return and va- moved from the tank and connected piping. <br /> por lines shall be disconnected. 2. Piping at tank openings that is not to be used fur- -- <br /> 3. The tank shall be filled completely with an ap- ther shall be disconnected. <br /> ® proved inert solid material. 3. Piping shall be removed from the ground. <br /> Exception:Residential heating oil tanks of <br /> 1,100 gallons(4164 L)or less,provided the Exception:Piping is allowed to be abandoned <br /> fill line is permanently removed to a point in place'where the fire code.official determines <br /> below grade to preventrefilling of the tank. thatremoval is notpractical.Abandoned piping <br /> shall be capped and safeguarded as required by <br /> 4. Remaining underground piping shall be capped the fire code official. <br /> or plugged. <br /> 5. A record of tank size,location and date of aban- 4. Tank openings shall be capped or plugged,leaving <br /> A recon t shall be retained. a.0.125-inch to 1/4-inch-diameter(3.2•mm to 6.4 <br /> mm)opening for pressure equalization. <br /> 6. All exterior above-grade fill piping shall be per- <br /> manently removed when tanks are abandonted 5. T shall be,purged.of vapor and inerted prior to <br /> removal. <br /> or removed. <br /> 3404.2.13.1.5 Reinstallation of underground 6. All exterior above-grade fill and vent piping shall <br /> tanks.Tanks which are to be reinstalled for flamma- be permanently removed. <br /> ble or combustible liquid service shall be in accor- Exception:Piping associated with bulk plants, <br /> dance with this chapter,ASME Boiler and Pressure terminal facilities and refineries., <br /> Vessel Code(Section VIII),API 12-P,API 1615,IiL 3404.2.14.2 Disposal. Tanks shall be,disposed of in <br /> 58 and UL 1316, accordance with federal,state and,local regulations, <br /> 3404.2.13.2 Above-ground tanks.Above-ground tanks 3404.3,Container and portable tank storAge..Storage of <br /> taken out of service shall comply with Sections flammable and combustible liquids in closed containers that do <br /> 3404.2,13.2.1 through 3404;2.13.2.3, not exceed 60 gallons(227 L)in individual capacity and porta- <br /> 3404.2.13.2.1 Temporarily out of.service. ble tanks that do not exceed 660 gallons(2498 L)in individual <br /> Above-ground tanks temporarily out of service shall capacity,and limited transfers in <br /> cidental ti}ereto,shall comply <br /> have all connecting lines isolated from the tank and be with this section. <br /> secured against tampering. 3404.3.1 Design,construction and capacity of containers <br /> Exception:In-place fire protection(foam)system'' and portable tanks.The design,construction and capacity <br /> lines. of containers for the storage of Class I,11 and,MA liquids <br /> 386 <br /> " 2007 CALIFORNIA FIRE CODE <br />