ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2012
RECORD_ID
PR0231939
PE
2361
FACILITY_ID
FA0002570
FACILITY_NAME
QUIK STOP MARKET #3144
STREET_NUMBER
7272
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95209
APN
094-040-13
CURRENT_STATUS
01
SITE_LOCATION
7272 WEST LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231939_7272 WEST_2008-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
299
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SYSWEM SET-UP REPOR (Pagel) <br /> SYSTEM SETUP COMMUNICATIONS SETUP IN-TANK SETUP <br /> - - - - - - - - - - - - - - - - - - - - ,- - - - - - - - - - - - - - - - <br /> HUG 2. 2010 8:05 AM <br /> T 1 :Ur-I eaded-Reyu I ar- <br /> PORT SETTINGS: P'RODUC'T CODE A <br /> THERMAL i_OEFF : .000700 <br /> S'�'STEP1 UNITS COMM BOARD I i RS-232 i TANK DIAMETER 9'2.00 <br /> U.S. BAUD RATE 9600 THNY PROFILE 4 PTS <br /> SYSTEM LHNGUHGE PAR IT,' NONE FULL VOL 9726 <br /> ENGLISH STOP BIT 2 STOP 69.0 I1-40H VOL 7910 <br /> S','STEM DATE TIME FOR11AT DATA LENGTH: 8 DATA 46.0 INOH VOL 4664 <br /> MON DD ',"':`i'! HH:mri:SS a°1 RS-232 SECURITY 23.0 INCH VOL 1618 <br /> CODE : DISABLED <br /> GUIK STOP 144 <br /> 7272 NRTH WST LANE COMM BOARD 2 (RS-'232) FLOHT SIZE: 4.0 IN. <br /> STO)i'TON Cm 95210 BAUD RATE : 9600 <br /> 209-952-681'2 PARITY NONE WATER WARNING 1 .5 <br /> STOP BIT 2 STOP HIGH WATER LIPIIT: 2.0 <br /> SHIFT TIME 1 : 6:00 AM DATA LENGTH: 7 DATA <br /> SHIFT TIME 2 DISABLED RS-232 SECURITY 11H:; OR LABEL VOL:: 9728 <br /> SHIFT TIME 3 : DISABLED CODE : DISABLED OVERFILL LIMIT 9044 <br /> SHIFT TIME 4 DISABLED 8755 <br /> COMM BOARD : 3 (ED 1M t HIGH PRODUCT 95`°b <br /> THNK PER TST NEEDED WRN RS-232 SECURITY 9241 <br /> DISABLED CGDE : DISABLED DELIVERi' LIMIT 15" <br /> TANK ANN TST NEEDED WRN 1459 <br /> DISABLED COMM BOARD 5 {S-SAT i <br /> BAUD RATE : 9600 LOW PRODUCT 450 <br /> LINE RE-ENHBLE METHOD PARITY NONE LEAK mi-ARI-1 LIMIT: 99 <br /> PASS LINE TEST STOP BIT 1 STOP SUDDEN LOSS LIMIT: 99 <br /> DATA LENGTH: 8 DATA THNK TILT 1 .15 <br /> LINE PER TST NEEDED WRN RS-232 SECURITY PROBE OFFSET 0.00 <br /> DISABLED CODE : DISABLED <br /> LINE ANN TST NEEDED WRN DTR NORMAL STATE: HIGH <br /> DISABLED SIPHON MHNIFOLDED TANKS <br /> TO: NONE <br /> PRINT TC VOLUMES AUTO TRANSIT SETTINGS: LINE MANIFOLDED TANKS <br /> ENABLED Tq: NONE <br /> AUTO LEHY HLHRM LIMIT <br /> TEMP COMPENSATION DISABLED <br /> VALUE (DEG F is 60.0 AUTO HIGH WATER LIMIT LEHK MIN PERIODI_: u".. <br /> STICK HEIGHT OFFSET DISABLED 0 <br /> DISABLED AUTO OVERFILL LIMIT <br /> ULLAGE: 90% DISABLED LEAK MIN ANNUAL : 011 <br /> AUTO LOW PRODUCT 0 <br /> H-PROT&'OL DATA FORMAT DISABLED <br /> HEIGHT AUTO THEFT LIMIT <br /> DAYLIGHT SAVING TIME DISABLED PERIODIC TEST TYPE <br /> ENABLED AUTO DELIVERY START STANDARD <br /> START DATE DISABLED <br /> APR WEEP I SUN AUTO DELIVER'.' END ANNUAL TEST FAIL <br /> START TIME DISABLED ALARM DISABLED <br /> 2:00 AM AUTO EXTERNAL INPUT ON <br /> END DATE DISABLED PERIODIC TEST FAIL <br /> OCT WEEK 6 SUN AUTO EXTERNAL INPUT OFF ALARM DISABLED <br /> END TIME DISABLED <br /> 2:00 HM AUTO SENSOR FUEL ALARM GROSS TEST FAIL <br /> DISABLED ALARM DISABLED <br /> RE-DIRECT LOCAL PRINTOUT AUTO SENSOR. WATER ALARM <br /> DISABLED DISABLED ANN TEST HVERHGINI:.: OFF <br /> AUTO SENSOR OUT ALARM PER TEST AVERAGING: OFF <br /> EURO PROTOCOL PREFIX DISABLED <br /> S TANK TEST NOTIFY: OFF <br /> THE TST SIPHON BREHK:OFF <br /> DELIVERY DELAY 1 MIN <br /> PUMP THRESHOLD 10.00 <br /> ©2010 Walton Engineering,Inc. <br />