Laserfiche WebLink
SYSEM SET—UP REPORTPage1) <br /> SYSTEM-SETUP - - - - - - COMMUNICATIONS SETUP IN-TANK SETUP <br /> AUG 10, 2009 8:48 AM - - - - - - - - -- - - - <br /> T 1 :01eaded—Regu1ar <br /> PORT SETTINGS: PRODUCT CODE A <br /> SYSTEM UNITSTHERMAL COEFF .000700 <br /> U.S. COMM BOARD I (RS-232) TANK DIAMETER 92.00 <br /> SYSTEM LANGUAGE BAUD RATE 9600 TANK PROFILE 4 PTS <br /> ENGLISH PARITY NONE FULL VOL 9728 <br /> SYSTEM DATE/TIME FORMAT STOP BIT 2 STOP 69.0 INCH VOL 7910 <br /> MON DD YYYY HH:MM:SS AM DATA LENGTH: 8 DATA 46.0 INCH VOL 4864 <br /> RS-232 SECURITY 23.0 INCH VOL 1818 <br /> QUIK STOP 144 CODE : DISABLED <br /> 7272 NRTH WST LANE COMM BOARD 2 (RS-232) FLOAT SIZE: 4.0 IN. <br /> STOCKTON CA 95209 BAUD RATE 1200 <br /> PARITY ODD WATER WARNING 1 .5 <br /> SHIFT TIME 1 6:00 AM STOP BIT I STOP HIGH WATER LIMIT: 2.0 <br /> SHIFT TIME 2 DISABLED DATA LENGTH: 7 DATA <br /> SHIFT TIME 3 DISABLED RS-232 SECURITY MAX OR LABEL VOL: 9728 <br /> SHIFT TIME 4 DISABLED CODE : DISABLED OVERFILL LIMIT 90% <br /> e755 <br /> TANK PER TST NEEDED WRN BOARD : 3 (ED INI HIGH PRODUCT 95% <br /> DISABLED RS-232 SECURITY 9241 <br /> TANK ANN TST NEEDED WRN CODE : DISABLED DELIVERY LIMIT 15% <br /> DISABLED 1459 <br /> COMM BOARD 5 (S-SAT <br /> LINE RE-ENABLE METHOD BAUD RATE 9600 LOW PRODUCT 450 <br /> PASS LINE TEST PARITY NONE LEAK ALARM LIMIT: 99 <br /> STOP BIT 1 STOP SUDDEN LOSS LIMIT: 99 <br /> LINE PER TST NEEDED WRN DATA LENGTH: 8 DATA TANK TILT K 15 <br /> DISABLED RS-232 SECURITY PROBE OFFSET 0.00 <br /> LINE ANN TST NEEDED WRN CODE : DISABLED <br /> DISABLED DTR NORMAL STATE: HIGH SIPHON MAN IFOLDED TANKS <br /> PRINT TC VOLUMES T#: NONE <br /> ENABLED AUTO TRANSMIT SETTINGS: LINE MANIFOLDED TANKS <br /> T#: NONE <br /> TEMP COMPENSATION AUTO LEAK ALARM LIMIT <br /> VALUE (DEG F ) : 60.0 DISABLED <br /> STICK HEIGHT OFFSET AUTO HIGH WATER LIM11. LEAK MIN PERIODIC: 0% <br /> DISABLED DISABLED 0 <br /> ULLAGE: 90% AUTO OVERFILL LIMIT <br /> DISABLED LEAK MIN ANNUAL 0% <br /> H-PROTOCOL DATA FORMAT AUTO LOW PRODUCT 0 <br /> HEIGHT DISABLED <br /> DAYLIGHT SAVING TIME AUTO THEFT LIMIT <br /> ENABLED DISABLED PERIODIC TEST TYPE <br /> START DATE AUTO DELIVERY START STANDARD <br /> APR WEEK I SUN DISABLED <br /> START TIME AUTO DELIVERY END ANNUAL TEST FAIL <br /> 2:00 AM DISABLED ALARM DISABLED <br /> END DATE AUTO EXTERNAL INPUT ON <br /> OCT WEEK 6 SUN DISABLED PERIODIC TEST FAIL <br /> END TIME AUTO EXTERNAL INPUT OFF ALARM DISABLED <br /> 2:00 AM DISABLED <br /> AUTO SENSOR FUEL ALARM GROSS TEST FOIL <br /> DISABLED ALARM DISABLED <br /> AUTO SENSOR WATER ALARM <br /> DISABLED ANN TEST AVERAGING: OFF <br /> AUTO SENSOR OUT ALARM PER TEST AVERAGING: OFF <br /> DISABLED <br /> TANK TEST NOTIFY: OFF <br /> TNK TST SIPHON BREAKOFF <br /> DELIVERY DELAY I MIN <br /> PUMP THRESHOLD 10.00% <br /> 2006 Walton Engineering,Inc. <br />