Laserfiche WebLink
SYWEM SET-UP REPOR <br />T 2:Unl Plus <br />1.5 <br />PRODUCT CODE <br />B <br />THERMAL COEFF <br />:.000700 <br />TANS: DIAMETER <br />92.00 <br />TANI: PROFILE <br />: 4 FTS <br />FULL VOL <br />9728 <br />69.0 INCH VOL <br />7910 <br />46.0 INCH VOL <br />4864 <br />23.0 INCH VOL <br />1818 <br />FLOAT SIZE: 4.0 IN. <br />WATER WARNING 1.5 <br />HIGH WATER LIMIT: 2.0 <br />MAX OR LABEL VOL: 9728 <br />OVERFILL LIMIT 90" <br />8755 <br />HIGH PRODUCT 954a <br />9241 <br />DELIVER', LIMIT 15'. <br />1459 <br />LOW PRODUCT 300 <br />LEAK ALARM LIMIT: 99 <br />SUDDEN LOSS LIMIT: 99 <br />THNI: TILT 3.25 <br />PROBE OFFSET 0.00 <br />SIPHON MANIFOLDED TANKS <br />TO: NONE <br />LINE MANIFOLIrED TANKS <br />TO: NONE <br />LEAK MIN PERIODIC: 0" <br />. 0 <br />LEAK MIN ANNUAL 0°0 <br />0 <br />T 3: P r ern i urn U n l d <br />1.5 <br />PRODUCT CODE <br />C <br />THERMAL COEFF :.000700 <br />7829 <br />TANI: DIAMETER <br />92.00 <br />TANI: PROFILE <br />4 PTS <br />FULL VOL <br />7829 <br />69.0 INCH VOL <br />6382 <br />46.0 INCH VOL <br />3914 <br />23.0 INCH VOL : <br />1447 <br />FLOAT SIZE: 4.0 IN. <br />WATER WARNING <br />1.5 <br />HIGH WATER LIMIT: <br />2.0 <br />MAS: OR LABEL VOL: <br />7829 <br />OVERFILL LIMIT <br />90°,* <br />7046 <br />HIGH PRODUCT <br />951% <br />7437 <br />DELIVER;' LIMIT <br />15% <br />1174 <br />LOW PRODUCT <br />300 <br />LEAK ALARM LIMIT: <br />99 <br />SUDDEN LOSS LIMIT: <br />99 <br />TANK TILT <br />1.50 <br />PROBE OFFSET <br />0.00 <br />SIPHON MANIFOLDED TANKS <br />TO: NONE <br />LINE MANIFOLDED TANKS <br />TO: NONE <br />LEAF MIN PERIODIC: 0 <br />0 <br />LEAK MIN ANNUAL (°. <br />0 <br />PERIODIC TEST TYPE PERIODIC TEST TYPE <br />STANDARD STANDARD <br />ANNUAL TEST FAIL <br />ALARM DISABLED <br />PERIODIC TEST FAIL <br />ALARM DISABLED <br />GROSS TEST FAIL <br />ALARM DISHBLED <br />ANN TEST AVERAGING: OFF <br />PER TEST AVERAGING: OFF <br />TANI: TEST NOTIFY: OFF <br />TNK TST SIPHON BREAKOFF <br />DELIVERY DELAY 1 M I N <br />PUMP THRESHOLD 10.00° <br />0 2006 Walton Engineering, Inc. <br />ANNUAL TEST FAIL <br />ALARM DISABLED <br />PERIODIC TEST FAIL <br />ALARM DISABLED <br />GROSS TEST FAIL <br />ALARM DISABLED <br />ANN TEST AVERAGING: OFF <br />PER TEST AVERAGING: OFF <br />TANI: TEST NOTIFY: OFF <br />TNK TST SIPHON BREAE:OFF <br />DELIVER' DELA`,' I M I N <br />PUMP THRESHOLD 10.00 <br />Page 2) <br />LEAK TEST.METHOD <br />TEST ON DATE : ALL TANK <br />FEB 6. 2007 <br />START TIME : DISABLED <br />TEST RATE :0.20 GHL HR <br />DURATION : 2 HOURS <br />TST EARLY STOP:DISHBLED <br />LEAK TEST REPORT FORMAT <br />NORMAL <br />LIQUID SENSOR SETUP <br />L 1:87 STP <br />TRI-STATE (SINGLE FLOHT) <br />CATEGORY : STP SUMP <br />L 2:89 STP <br />TRI-STHTE (SINGLE FLOAT) <br />CATEGORY : STP SUMP <br />L 3: 91 STP <br />TR.I-STATE (SINGLE FLOAT) <br />CHTEGORY : STP SUMP <br />L 4:87 ANNULAR <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : ANNULAR SPACE <br />L 5:89 ANNULAR <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : ANNULAR SPACE <br />L 6:91 ANNULAR <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : ANNULAR SPACE <br />L 7:DISP 1-2 <br />TRI-STHTE (SINGLE FLOAT) <br />CATEGORY : DISPENSER PAN <br />L B:DISP 3-4 <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : DISPENSER PAN <br />L 9:DISP 5-6 <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : DISPENSER PAN <br />