Laserfiche WebLink
SY EM SET-UP REPOR (Paget) <br /> T 2:Midsrade_Unlead T 3:Premium_Unlead LEAK TEST METHOD <br /> PRODUCT CODE C PRODUCT CODE B - - - - - - - - - - - - <br /> THERMAL COEFF : .000700 THERMAL COEFF : .000700 TEST ON DATE : ALL TANK <br /> TANK DIAMETER 92.00 TANK DIAMETER 92.00 FEB 6, 2007 <br /> TANK PROFILE 4 PTS TANK PROFILE 4 PTS START TIME : DISABLED <br /> FULL VOL 9728 FULL VOL 7829 TEST RATE :0.20 GAL/HR <br /> 69.0 INCH VOL 7910 69.0 INCH VOL 6382 DURATION 2 HOURS <br /> 46.0 INCH VOL 4864 46.0 INCH VOL 3914 <br /> 23.0 INCH VOL 1818 23,0 INCH VOL 1447 TST EARLY STOP:DISABLED <br /> LEAK TEST REPORT FORMAT <br /> FLOAT SIZE: 4,0 IN. FLOAT SIZE: 4.0 IN. NORMAL <br /> WATER WARNING 1 .5 WATER WARNING 1 .5 LIQUID SENSOR SETUP <br /> HIGH WATER LIMIT: 2.0 HIGH WATER LIMIT: 2.0 - - - - _ <br /> MAX OR LABEL VOL: 9728 MAX OR LABEL VOL: 7829 L 1 :87 STP <br /> OVERFILL LIMIT 90% OVERFILL LIMIT 90% TRI-STATE (SINGLE FLOAT) <br /> 8 <br /> HIGH PRODUCT 955 HIGH PRODUCT 7046 <br /> CATEGORY STP SUMP <br /> 9241 7437 <br /> DELIVERY LIMIT 15% DELIVERY LIMIT 15% L 2:89 STP <br /> 1459 1174 TRI-STATE (SINGLE FLOAT) <br /> LOW PRODUCT 300 LOW PRODUCT 300 CATEGORY : STP SUMP <br /> LEAK ALARM LIMIT: 99 LEAK ALARM LIMIT: 99 <br /> SUDDEN LOSS LIMIT: 99 SUDDEN LOSS LIMIT 99 L 3:91 STP <br /> TANK TILT 3.25 TANK TILT 1 .50 TRI-STATE (SINGLE FLOAT) <br /> PROBE OFFSET 0,00 PROBE OFFSET 0.00 CATEGORY : STP SUMP <br /> SIPHON MANIFOLDED TANKS SIPHON MANIFOLDED TANKS L 4:87 ANNULAR <br /> TO: NONE TO: NONE TRI-STATE (SINGLE FLOAT) <br /> LINE MANIFOLDED TANKS LINE MANIFOLDED TANKS CATEGORY : ANNULAR SPACE <br /> TO: NONE TO: NONE <br /> LEAK MIN PERIODIC: 0% LEAK MIN PERIODIC: 0% L 5:89 ANNULAR <br /> 0 0 TRI-STATE (SINGLE FLOAT) <br /> LEAK MIN ANNUAL 0% LEAK MIN ANNUAL 0% CATEGORY : ANNULAR SPACE <br /> 0 0 <br /> PERIODIC TEST TYPE PERIODIC TEST TYPE L -S ANNULAR <br /> TRI-S <br /> STANDARD STANDARD TATE (SINGLE FLOAT) <br /> CATEGORY : ANNULAR SPACE <br /> ANNUAL TEST FAIL ANNUAL TEST FAIL <br /> ALARM DISABLED ALARM DISABLED <br /> PERIODIC TEST FAIL PERIODIC TEST FAIL L 7:DISP 1-2 <br /> TRI-STATE (SINGLE FLOAT) <br /> ALARM DISABLED ALARM DISABLED <br /> CATEGORY DISPENSER FAN <br /> GROSS TEST FAIL GROSS TEST FAIL <br /> ALARM DISABLED ALARM DISABLED <br /> ANN TEST AVERAGING: OFF ANN TEST AVERAGING: OFF L B:DISP 3-4 <br /> TRI-STATE (SINGLE FLOAT) <br /> PER TEST AVERAGING: OFF PER TEST AVERAGING: OFF <br /> CATEGORY DISPENSER PAN <br /> TANK TEST NOTIFY: OFF TANK TEST NOTIFY: OFF <br /> TNK TST SIPHON BREAK:OFF TNK TST SIPHON BREAKOFF L 9:DISP 5-6 <br /> DELIVERY DELAY 1 MIN DELIVERY DELAY 1 MIN TRI-STATE (SINGLE FLOAT) <br /> PUMP THRESHOLD 10.00% PUMP THRESHOLD 10.00% CATEGORY : DISPENSER PAN <br /> ®2012 Walton Engineering,Inc. <br />