Laserfiche WebLink
0 <br />Page 1 of 6 <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232�t <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />SEP U I YUIb <br />J J "-._ ' <br />Facility Name:: Facility Phone: <br />QUIK STOP MARKET #3144 209 952-8812 <br />Date: <br />Jul 27 2016 <br />Facility Address: <br />7272 WEST LN STOCKTON CA 95209 <br />CERS ID: <br />10180967 <br />Inspection Contact: <br />Somal Balwinder <br />Title: <br />franchisee <br />Phone: <br />209 952-8812 <br />Inspection Type. <br />ROUTINE INSPECTION - Operating Permit <br />Program: <br />2361 - UST FACILITY <br />Consent For: <br />El Inspection 0 Photos 0 Samples <br />Consent Given By: <br />I Somal Balwinder. Franshicee <br />Service Technician Onsite: <br />Jessie Wadkins <br />Exp. Date: <br />04/03/2017 <br />Designated Operator: <br />Curtis Caar enter <br />Exp. Date: <br />03/16/2017 <br />Service Technician Manufacturer's Training <br />Veeder Root, 04/26/17; VMI 02/11/18 <br />C R = California Code of Regulations HSC = Health and Safety Code CFR = Code of Federal Regulations <br />V = Violation R = Repeat violation COS = Corrected on site during Inspection <br />101 <br />HSC 25284 <br />No permit to operate <br />n V <br />n R <br />❑ COS <br />102 <br />HSC 25284(a)(3) <br />No written agreement between tank owner and tank operator to monitor the tank system <br />o V <br />❑ R <br />o COS <br />103 <br />HSC 25292.2 <br />Current financial responsibility documents not submitted <br />■ V <br />❑ R <br />❑ COS <br />104 <br />CCR 2711 <br />UST operating permit application for facility and tank information not submitted or current <br />❑ V <br />❑ R <br />❑ COS <br />105 <br />CCR 2632(d)(1) <br />Failed to have an approved UST monitoring plan <br />❑ V <br />❑ R <br />❑ COS <br />106 <br />CCR 2632(d)(2) <br />Failed to have an approved UST response plan <br />❑ V <br />❑ R <br />a COS <br />107 <br />CCR 2632(d)(1)(C) <br />Plot plan/site map not submitted or failed to completely show where monitoring is performed <br />o V <br />❑ R <br />❑ COS <br />108 <br />CCR 2637(f), 2638(e) <br />Failed to notify the EHD 48 hours prior to conducting testing <br />o V <br />o R <br />❑ COS <br />109 <br />CCR 2637 <br />Failed to test secondary containment <br />❑ V <br />o R <br />❑ COS <br />110 <br />CCR 2637(e) <br />Failed to submit secondary containment test report within 30 days <br />❑ V <br />❑ R <br />❑ COS <br />111 <br />CCR 2638(a) <br />Failed to test monitoring and teak detection equipment annually <br />n V <br />n R <br />❑ COS <br />112 <br />HSC 25284.2 <br />Failed to test spill containers annually <br />❑ V <br />❑ R <br />a COS <br />113 <br />CCR 2638(d) <br />Failed to submit monitoring system certification test report within 30 days <br />❑ V <br />❑ R <br />❑ COS <br />114 <br />CCR 2636(0 <br />Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down <br />a V <br />a R <br />n COS <br />115 <br />CCR 2715(a) <br />Failed to inform the EHD of designated operator identification or change within 30 days <br />❑ V <br />❑ R <br />❑ COS <br />116 <br />CCR 2715 <br />Designated operator, service tech or installer did not possess current ICC certification <br />❑ V <br />❑ R <br />o COS <br />117 <br />CCR 2663 <br />Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after <br />❑ V <br />❑ R <br />a COS <br />118 <br />CCR 2663 <br />Failed to submit tank lining certification within 30 days or to conduct proper tests <br />n V <br />a R <br />o COS <br />119 <br />HSC 25299 <br />Documents were falsified or misrepresented <br />❑ V <br />❑ R <br />❑ COS <br />120 <br />CCR 2635(d) <br />Failed to submit UST Certification of Installation/Modification <br />a V <br />o R <br />❑ COS <br />121 <br />CCR 2712(f) <br />Failed to submit a written response within 30 days of receiving an inspection report <br />■ V <br />■ R <br />❑ COS <br />122 CCR 2631 Q) <br />201 CCR 2712(b) <br />Failure to submit UST system component statement of compatibility for substance stored <br />Failed to maintain alarm logs and/or records of follow up actions <br />❑ V <br />■ V <br />❑ R <br />■ R <br />❑ COS <br />❑ COS <br />202 CCR 2712(b) <br />Failed to maintain cathodic protection test records on site for at least 6 1/2 years <br />❑ V <br />o R <br />in COS <br />203 CCR 2712(b) <br />Failed to maintain records of monitoring, repair, lining, and upgrades on site <br />■ V <br />■ R <br />❑ COS <br />Page 1 of 6 <br />