My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
7272
>
2300 - Underground Storage Tank Program
>
PR0231939
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/23/2023 12:58:25 PM
Creation date
6/3/2020 9:55:08 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231939
PE
2361
FACILITY_ID
FA0002570
FACILITY_NAME
QUIK STOP MARKET #3144
STREET_NUMBER
7272
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95209
APN
094-040-13
CURRENT_STATUS
01
SITE_LOCATION
7272 WEST LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231939_7272 WEST_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
367
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />Date: <br />QUIK STOP MARKET #3144 <br />7272 WEST LN STOCKTON <br />JuIV 30 2015 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />207 <br />CCR 2715 Designated operator did not inspect all required items and/or the inspection reports not completed. <br />The designated operator failed to check and note the correct test dates for the last Monitoring System Certification <br />and Spill Bucket testing on the September 2014 designated operator monthly inspection report. The test date on the <br />D.O report was August 9, 2014. The correct date is August 1, 2014. During the monthly inspection, the designated <br />operator shall check that all required testing and maintenance for the UST system have been completed and <br />document the dates they were done. Ensure that designated operators performing monthly inspections at this facility <br />are including all of the required information on the reports. <br />The designated operator failed to document all the alarms from the attached alarm history on the December 2014 <br />designated operator monthly inspection report and failed to check that they were responded to appropriately. The <br />missing alarms include: <br />- 1-1: 87 STP Sump- November 7, 2014 Fuel Alarm <br />- L7: Dispenser 1-2- November 7, 2014 Fuel Alarm <br />During the monthly inspection, the designated operator shall review the alarm history for the previous month, check <br />that each alarm was documented and responded to appropriately, and attach a copy of the alarm history with <br />documentation taken in response to any alarms to the monthly report. Ensure that designated operators performing <br />monthly inspections at this facility are including all of the required information on the reports. <br />This is a repeat violation, Class II. <br />306 <br />CCR 2630(d) Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity. <br />The 87 STP sump and the 89 STP sump sensors were raised approximately three inches off the lowest point of the <br />sump and not located to detect a leak at the earliest opportunity. Monitoring equipment shall be maintained to be <br />able to detect a leak at the earliest possible opportunity. The sensors were relocated to the lowest point of the sump <br />by the service technician. Ensure that all monitoring equipment is maintained to detect a leak at the earliest <br />opportunity. This was corrected on site. <br />This is a Class II violation. <br />307 <br />CCR 2632(c) Monitoring system of the interstitial space of a double walled system not maintained. <br />The 91 annular sensor failed to activate an audible and visual alarm when tested and, therefore, the tank is not <br />monitored. The interstitial space shall be monitored with a monitoring system connected to an audible and visual <br />alarm system. The sensor was replaced and retested during the inspection. A "UST Retrofit Verification with <br />Inspector Already Onsite" form has been completed and provided to the operator and contractor. This was corrected <br />on site. <br />This is a Class II violation. <br />Received b <br />Inspector: <br />Phone: <br />Date: <br />(initial):V:�� <br />I FATINAH ZAREEF, REHS <br />(209) 953-7311 <br />07/30/2015 <br />Page 5 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.