San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sigov.org/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />Date: <br />QUIK STOP MARKET #3144 <br />7272 WEST LN, STOCKTON <br />July 24, 2017 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS 11, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />315 <br />HSC 25291(e) Water in secondary containment not removed, analyzed, and properly disposed of (pre -Jul 2003). <br />Liquid was observed in the 87 -product, 89 -product, and 91 -product submersible turbine pump (STP) sumps and the <br />89 -product and 91 -product fill sumps. If water could enter into the secondary containment by precipitation or <br />infiltration, it must be removed and disposed of properly. The service technician removed approximately three cups <br />of liquid from each of the three STP sumps and a trace of liquid from the 89 -product and 91 -product fill sumps. <br />Ensure that all sumps and annular spaces are maintained free of liquid. <br />This was corrected on site. <br />This is a repeat violation, Class II. <br />Overall Inspection Comments: <br />Complete and submit a copy of the Return to Compliance Certification form to the Environmental Health <br />Department (EHD) with a statement documenting the corrective actions that have been or will be taken for each <br />violation, and any supporting paperwork, by August 23, 2017. <br />Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br />documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br />Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer (if <br />applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br />Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br />ti <br />EI�dV'98-9°vi7itisi+� inn �o—'e i4. L.I1°�, <br />AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING <br />THIS FACILITY BACK INTO COMPLIANCE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />Received by: Date: July 24, 2017 <br />Inspector: <br />Inspector Phone: <br />Alto Printed Name and Title: <br />VICKI MCCARTNEY, Senior REHS <br />(209) 468-9852 <br />Balwinder Somal, Franchisee <br />FA0002570 PR0231939 SC001 07/24/2017 <br />EHD 23-01 Rev. 09/22116 Page 5 of 6 Underground Storage Tank Program OIR <br />