� s <br /> TAI HFAI-Th <br /> 882-D1U1 P FF14 1 SFP1 VI1C <br /> WRITTEN MONITORING PROCEDUR <br /> UNDERGROUND STORAGE TANK MONITORIN ' <br /> This monitoring program must be kept at the UST location at all times. The information on this monitoring <br /> program are conditions of the operating permit. The permit holder must notify San Joaquin County <br /> Environmental Health Division,phone(209)468-3420 within 30 days of any changes to the monitoring <br /> procedures, unless required to obtain approval before making the change. <br /> Required by 23 CCR,Division 4,Chapter 16,Sections 2632(d)and 2641(h) . <br /> Facility Name Lawrence Livermore National Laboratory Site 300, Tank 882-D1U1 <br /> Facility Address Corral Hollow Road south of Tracy,California <br /> A. Describe the frequency of performing the monitoring: <br /> Tank Continuous <br /> Piping Continuous <br /> B. What methods and equipment,identified by name and model,will be used for performing <br /> the monitoring: <br /> Tank Universal Leak Alert Hazardous Substance Sensor(Alarm Panel Model LA-02, <br /> Liquid Probe Model LALS-1). The liquid probe is installed in the tank's annular space at <br /> the low point. <br /> Piping Universal Leak Alert Hazardous Substance Sensor(Alarm Panel Model LA-02, <br /> Liquid Probe Model LALS-1). The liquid probe is installed in the double-wall piping <br /> SUMP. <br /> C. Describe the location(s)where the monitoring will be performed(facility plot plan <br /> should be attached): On the southwest side of Building 882. <br /> D. List the name(s)and title(s)of the people responsible for performing the monitoring <br /> and/or maintaining the equipment: Person(s)designated by Don Hill,Senior Supervisor <br /> for Maintenance Mechanics. <br /> E. Reporting format for monitoring: <br /> Tank A sign-off sheet is maintained at the monitoring system control panel. The sheet is <br /> initialed at the time of completion of the weekly inspection and alarm trial. Completed <br /> sheets are maintained in the Maintenance Mechanics files in Building 875. <br /> Piping The inspection and alarm trial for the tank system includes the piping system. <br /> F. Describe the preventive maintenance schedule for the monitoring equipment. Note: <br /> Maintenance must be in accordance with the manufacturers'maintenance schedule but <br /> not less than every 12 months: At least annually,the tank interstitial space sensor and <br /> the piping sump sensor will be removed and inspected for evidence of damage or <br /> deterioration. The monitoring system monitoring manual will be used to verify <br /> the operational condition of all system capabilities. Operator will complete the form at <br /> Appendix A,Operator's Monitoring Report. Documentation will be maintained in <br /> the Building 873 Alarm Electricians files. <br /> G. Describe the training necessary for the operation of UST system,including piping, <br /> and the monitoring equipment: At the time of job assignment and not less frequently than <br /> annually thereafter, each operator and backup operator will read the monitoring system <br /> operating instruction manuals,and use the operating instruction manual to verify the <br /> operation condition of all capabilities by operating system. Each trained person will <br /> complete the form at Appendix B,Training Documentation. Documentation will be <br /> maintained in the Building 875 Maintenance Mechanics files. <br /> 12/19/94 Rev. <br />