My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_FILE 11
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CORRAL HOLLOW
>
15999
>
2300 - Underground Storage Tank Program
>
PR0231945
>
COMPLIANCE INFO_FILE 11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/30/2022 2:48:03 PM
Creation date
6/3/2020 9:55:24 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
FILE 11
RECORD_ID
PR0231945
PE
2361
FACILITY_ID
FA0003934
FACILITY_NAME
Lawrence Livermore National Lab - Site 300
STREET_NUMBER
15999
Direction
W
STREET_NAME
CORRAL HOLLOW
STREET_TYPE
RD
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
15999 W CORRAL HOLLOW RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231945_15999 W CORRAL HOLLOW_FILE 11.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
403
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
} <br />Monitoring System Certification <br />Site Address: Site 300 -Bldg. 871, Corral Hollow Road, TWY, CA 95376 Date: 10-28-2003 <br />D. Results of Testing/Servicing <br />Software Version Installed: 612760-006-C <br />rmmnlata tha fallnwina nhwd-klic4• <br />■ Yes <br />❑ No* <br />Is the audible alarm o erational? <br />■ Yes <br />E3 No* <br />Is the visual alarm operational? <br />■ Yes <br />❑ No* <br />Were all sensors visual) inspected, functional) tested, and confirmed operational? <br />■ Yes <br />❑ No* <br />Were all sensors installed at lowest point of secondary containment and positioned so that other equipment <br />ro <br />will not interfere with their er operation? <br />■ Yes <br />El No* <br />If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modern) <br />E3 N/A <br />operational? <br />❑ Yes <br />❑ No* <br />For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br />■ N/A <br />monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate <br />positive shut -down? (Check all that apply) ❑ Sump/Trench Sensors; ❑ Dispenser Containment Sensors. <br />Did you confirm positive shut -down due to leaks and sensor failureldisconnection? L3 Yes; 13 No. <br />■ Yes <br />❑ No* <br />For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br />❑ N/A <br />mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br />fill point(s) and o eratin properly? If so, at what cent of tank ca aei does the alarm trigger? 90% <br />El Yes* <br />■ No <br />Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment <br />r laced and list the manufacturer name and model for all replacement arts in Section E, below. <br />El Yes* <br />■ No <br />Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br />❑ Product; Ll Water. If es, describe causes in Section E, below. <br />■ Yes <br />El No* <br />Was monitoringsystem set -u reviewed to ensure propersettings? Attach set u reports, if applicable <br />■ Yes <br />Ll No* <br />Is all monitorin ui mento erationapE l manufacturer's s ecification s? <br />* In Section E below, describe how and when these deficiencies were or will be corrected. <br />E. Comments: <br />The tank has a mechanical overfill drop tube. This is a suction system. <br />Page 2 of 3 03/01 <br />
The URL can be used to link to this page
Your browser does not support the video tag.