Laserfiche WebLink
e b <br />Monitoring System Certification <br />Site Address: Site 300 -Bldg. 875, Corral Hollow Road, Tracy, CA 95376 - Date: 10-28-2003 <br />D. Results of Testing/Servicing <br />Software Version Installed: 612760-001-H <br />rmmnlete the fallnwino rherklict- <br />■ Yes <br />❑ No* <br />Is the audible alarm operational? <br />■ Yes <br />❑ No* <br />Is the visual alarm operational? <br />■ Yes <br />❑ No* <br />Were all sensors visually inspected, functionally tested, and confirmed operational? <br />■ Yes <br />❑ No* <br />Were all sensors installed at lowest point of secondary containment and positioned so that other equipment <br />will not interfere with their proper operation? <br />■ Yes <br />❑ No* <br />If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) <br />❑ N/A <br />operational? <br />❑ Yes <br />❑ No* <br />For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br />■ N/A <br />monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate <br />positive shut -down? (Check all that apply) ❑ Sump/Trench Sensors; ❑ Dispenser Containment Sensors. <br />Did you confirm positive shut -down due to leaks and sensor failure/disconnection? ❑ Yes; ❑ No. <br />■ Yes <br />❑ No* <br />For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br />❑ N/A <br />mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br />fill point(s) and operating ro 1 . If so, at what percent of tank EMacity does the alarm tri er? 90% <br />❑ Yes* <br />■ No <br />Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment <br />replaced and list the manufacturer name and model for all replacement parts in Section E, below. <br />❑ Yes* <br />■ No <br />Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br />❑ Product; ❑ Water. If yes, describe causes in Section E, below. <br />■ Yes <br />❑ No* <br />Was monitoring stem set-up reviewed to ensure proper settings? Attach set up r rts, if applicable <br />■ Yes <br />❑ No* <br />Is all monitoring equipment 2=ational Rer manufacturer's specifications? <br />* In Section E below, describe how and when these deficiencies were or will be corrected. <br />E. Comments: <br />The tank has a mechanical overfill drop tube. This is a suction system. <br />Remote alarm display lamp was not operational, customer to replace bulb ASAP. <br />Page 2 of 3 03/01 <br />