My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_FILE 12
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CORRAL HOLLOW
>
15999
>
2300 - Underground Storage Tank Program
>
PR0231945
>
COMPLIANCE INFO_FILE 12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/30/2022 4:43:06 PM
Creation date
6/3/2020 9:55:27 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
FILE 12
RECORD_ID
PR0231945
PE
2361
FACILITY_ID
FA0003934
FACILITY_NAME
Lawrence Livermore National Lab - Site 300
STREET_NUMBER
15999
Direction
W
STREET_NAME
CORRAL HOLLOW
STREET_TYPE
RD
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
15999 W CORRAL HOLLOW RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231945_15999 W CORRAL HOLLOW_FILE 12.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
472
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
IED PROGRAM CONSOLIDATED FORM-TA (o� <br /> U ��� <br /> UN GROUND STORAGE TANKS-TANK P E 1 <br /> 87 G W 0 <br /> Two a es er tank <br /> Page 1 of 2 <br /> TYPE OF ACTION ❑ 1.NEW PERMIT ❑ 4.AMENDED PERMIT ® 5.CHANGE OF INFORMATION ❑ 6.TEMPORARY TANK CLOSURE 430. <br /> (Check one item only) ❑ 3.RENEWAL PERMIT ❑ 7.PERMANENTLY CLOSED ON SITE <br /> (Specify reason) (Specify reason) ❑ 8.TANK REMOVED <br /> BUSINESSNAME(SameasFAquTYNAMEorDBA-DoingBusinessAs) 3. FACILITY ID: <br /> Lawrence Livermore National Laboratory-Site 300 <br /> LOCATION WITHIN SITE(optional) 431. <br /> Building 879-South side <br /> I.TANK DESCRIPTION(A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br /> TANK ID# 879-G3U1 432. TANK MANUFACTURER 433. COMPARTMENTALIZED TANK ❑Yes ® No 434. <br /> 390002319450505184 TRU SCO If"Yes,'complete one page for each compartment. <br /> DATE INSTALLED(YEAR/MO) 435. TANK CAPACITY IN GALLONS 436. NUMBER OF COMPARTMENTS 437. <br /> 1994/06 15,000 1 <br /> ADDITIONAL DESCRIPTION(For local use only) 438. <br /> II.TANK CONTENTS <br /> TANK USE 439. PETROLEUM TYPE 440. <br /> ® 1. MOTOR VEHICLE FUEL ®1a. REGULAR UNLEADED ❑2. LEADED [15. JET FUEL <br /> (If checked,complete Petroleum Type) ❑1b. PREMIUM UNLEADED ❑3. DIESEL ❑6. AVIATION GAS <br /> ❑ 2. NON-FUEL PETROLEUM ❑1c. MIDGRADE UNLEADED ❑4. GASOHOL ❑99.OTHER: <br /> ❑ 3. CHEMICAL PRODUCT COMMON NAME (from Hazardous Materials Inventory page) 441. CAS#(from Hazardous Materials Inventory page) 442. <br /> ❑ 4. HAZARDOUS WASTE Unleaded Gasoline 8006-61-9 <br /> (Includes Used Oil) <br /> ❑ 95.UNKNOWN <br /> III.TANK CONSTRUCTION <br /> TYPE OF TANK ❑1. SINGLE WALL ❑3. SINGLE WALL WITH EXTERIOR ❑5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443. <br /> (Check one item only) MEMBRANE LINER ❑95. UNKNOWN <br /> ®2. DOUBLE WALL ❑4. SINGLE WALL IN A VAULT ❑99. OTHER <br /> TANK MATERIAL-primary tank ®1. BARE STEEL ❑3. FIBERGLASS/PLASTIC ❑5. CONCRETE ❑95.UNKNOWN 444. <br /> (Check one item only) ❑2. STAINLESS STEEL ❑4. STEEL CLAD W/FIBERGLASS ❑8. FRP COMPATIBLE ❑99.OTHER: <br /> REINFORCED PLASTIC FRP W/100%METHANOL <br /> TANK MATERIAL-secondary tank ❑1. BARE STEEL ❑3. FIBERGLASS/PLASTIC ❑8. FRP COMPTIBLE W/100%METHANOL ❑95.UNKNOWN 445. <br /> (Check one item only) ❑2. STAINLESS STEEL ®4. STEEL CLAD W/FIBERGLASS ❑9. FRP NON-CORRODABLE JACKET ❑99.OTHER <br /> REINFORCED PLASTIC(FRP) ❑10. COATED STEEL <br /> ❑5. CONCRETE <br /> TANK INTERIOR LINING ❑1.RUBBER LINED ❑3.EPDXY LINING ❑5.GLASS LINING [195.UNKNOWN 446. DATE INSTALLED 447. <br /> OR COATING ❑2.ALKYD LINING ❑4.PHENOLIC LINING ®6.UNLINED ❑99.OTHER <br /> Check one item only) <br /> OTHER CORROSION ❑1.MANUFACTURED CATHODIC ❑3.FIBERGLASS REINFORCED PLASTIC ❑95.UNKNOWN 448. DATE INSTALLED 449. <br /> PROTECTION PROTECTION ❑4.IMPRESSED CURRENT ❑99.OTHER <br /> (if Applicable) ❑2.SACRIFICIAL ANODE <br /> SPILL AND OVERFILL YEAR INSTALLED 450. TYPE 451. OVERFILL PROTECTION EQUIPMENT: YEAR INSTALLED 452. <br /> (Check all that apply) ®1.SPILL CONTAINMENT 2005 ®1.ALARM 1994 ®3.FILL TUBE SHUT OFF VALVE 2005 <br /> ®2.DROP TUBE 2005 ❑2.BALL FLOAT ❑4.EXEMPT <br /> ®3.STRIKER PLATE 1994 <br /> IV.TANK LEAK DETECTION <br /> (A description of the monitoring program shall be submitted to the local agency.) <br /> IF SINGLE WALL TANK 453• IF DOUBLE WALL TANK OR TANK WITH BLADDER 454. <br /> (Check all that apply) (Check one item only) <br /> ❑1. VISUAL(EXPOSED PORTION ONLY) ❑5. MANUAL TANK GAUGING(MTG) ❑1.VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑2. AUTOMATIC TANK GAUGING(ATG) 06.VADOSE ZONE 1812. CONTINUOUS INTERSTITIAL MONITORING <br /> ❑3. CONTINUOUS ATG ❑7.GROUNDWATER ❑3. MANUAL MONITORING <br /> [14. STATISTICAL INVENTORY RECONCILIATION ❑8.TANK TESTING <br /> (SIR)+BIENNIALTANK TESTING ❑99. OTHER <br /> V.TANK CLOSURE INFORMATION/ PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455. ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456' 1 TANK FILLED WITH INERT MATERIAL? 457. <br /> NA gallons ❑Yes ❑ No <br /> UPCF hwfwrc-b(1/99)-1/4 http://www.unidoes.org Rev.02/16/00 <br />
The URL can be used to link to this page
Your browser does not support the video tag.