Laserfiche WebLink
PROGRAM CONSOLIDATED FORM-TAU#IFIED <br /> RGROUND STORAGE TANKS-TANK PME 2 879-G3U1 WGMG05:115 <br /> Pa e2of2 <br /> VI.PIPING CONSTRUCTION(check all thatapply)UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SYSTEM TYPE ®1.PRESSURE SPLY Cl 2.SUCTION ®3.GRAVITY RTN 458. ❑1.PRESSURE ❑2.SUCTION ❑3.GRAVITY 459 <br /> CONSTRUCTION/ ❑1.SINGLE WALL ❑3.LINED TRENCH ❑99.OTHER 460 ❑1 SINGLE WALL ❑95.UNKNOWN 462 <br /> MANUFACTURER <br /> ®2.DOUBLE WALL ❑95.UNKNOWN ❑2.DOUBLE WALL ❑99 OTHER <br /> MANUFACTURER steel/Ameron-FRP 461. <br /> MANUFACTURER 463 <br /> ®1.BARE STEEL ❑6.FRP COMPATIBLE WI100°/METHANOL ❑1.BARE STEEL. ❑6.FRP COMPATIBLE W/100%METHANOL <br /> ❑2.STAINLESS STEEL ❑7.GALVANIZED STEEL ❑2.STAINLESS STEEL ❑7.GALVANIZED STEEL <br /> ❑3.PLASTIC COMPATIBLE WITH CONTENTS ❑95.UNKNOWN ❑3 PLASTIC COMPATIBLE WI CONTENTS ❑8,FLEXIBLE(HDPE) ❑99.OTHER <br /> ®4.FIBERGLASS ❑8.FLEXIBLE(HDPE) ❑99.OTHER ❑4 FIBERGLASS ❑9.CATHODIC PROTECTION <br /> ❑5.STEEL W/COATING ❑9.CATHODIC PROTECTION 464 ❑5.STEEL W/COATING ❑95.UNKNOWN 465 <br /> VII.PIPING LEAK DETECTION(Check all that apply)(A description of the monitoring program shal be submitted to the local agency.) <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SINGLE WALL PIPING 466. SINGLE WALL PIPING 467 <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> ❑1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT-OFF FOR ❑ 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF FOR <br /> LEAK, SYSTEM FAILURE, AND SYSTEM DISCONNECTION + AUDIBLE AND VISUAL LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND VISUAL <br /> ALARMS, ALARMS. <br /> C ❑2. MONTHLY 0.2 GPH TEST <br /> ❑2. MONTHLY 0.2 GPH TEST <br /> ❑3. ANNUAL INTEGRITY TEST(0.1 GPH) ❑3. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑4. DAILY VISUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS CONVENTIONAL SUCTION SYSTEMS(Check all that apply) <br /> ❑5. DAILY VISUAL MONITORING OF PUMPING SYSTEM +TRIENNIAL PIPING INTEGRITY <br /> TEST(0.1 GPH) ElS. DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> T <br /> SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): ❑6. TRIENNIAL INTEGRITY TEST(0.1 GPH) <br /> ❑7. SELF MONITORING SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING). <br /> GRAVITY FLOW ❑7. SELF MONITORING <br /> 4 <br /> 139. BIENNIAL INTEGRITY TEST(0.1 GPH) GRAVITY FLOW(Check all that apply): <br /> ❑8 DAILY VISUAL MONITORING <br /> ❑9. BIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SECONDARILY CONTAINED PIPING SECONDARILY CONTAINED PIPING <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> 10.CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE&VISUAL ALARMS AND(Check one) 10.CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE&VISUAL ALARMS AND(Check one) <br /> a ®a.AUTO PUMP SHUT OFF WHEN A LEAK OCCURS ❑a.AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> ❑b.AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE,&SYSTEM DISCONNECTION ❑b.AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE&SYSTEM DISCONNECTION <br /> 5 <br /> ❑c.NO AUTO PUMP SHUT OFF ❑c.NO AUTO PUMP SHUT OFF <br /> ®11.AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITH FLOW SHUT OFF OR <br /> RESTRICTION ❑11.AUTOMATIC LEAK DETECTOR <br /> ❑12.ANNUAL INTEGRITY TEST(0.1 GPH) ❑12.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> SUCTION/GRAVITY SYSTEM SUCTIONIGRAVITY SYSTEM <br /> ❑13.CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS ❑13.CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS <br /> EMERGENCY GENERATORS ONLY(Check all that apply) EMERGENCY GENERATORS ONLY(Check all that apply) <br /> ❑14.CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF+AUDIBLE&VISUAL ❑14.CONTINUOUS SUMP SENSOR WIT_ HOUT AUTO PUMP SHUT OFF+AUDIBLE&VISUAL <br /> ALARMS ALARMS <br /> ❑15.AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITHOUT FLOW SHUT OFF OR ❑15.AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST <br /> RESTRICTION ( . ) <br /> ❑16.ANNUAL INTEGRITY TEST(0.1 GPH) ❑16.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑17.DAILY VISUAL CHECK ❑17.DAILY VISUAL CHECK <br /> VIII.DISPENSER CONTAINMENT <br /> DISPENSER CONTAINMENT 468. ®1.FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE ❑4.DAILY VISUAL CHECK 469 <br /> DATE INSTALLED ❑2.CONTINUOUS DISPENSER PAN SENSOR+AUDIBLE AND VISUAL ALARMS ❑S.TRENCH/LINER MONITORING <br /> June 1994 ❑3.CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR DISPENSER+AUDIBLE&VISUAL ALARMS ❑6.NONE <br /> ( IX.OWNERIOPERATOR SIGNATURE <br /> I certify that the information provided herein is true and accurate to the best of my knowledge. <br /> SIGNATURE OF OWNEWOPE OR DATE: n ' ` O 470, <br /> NAME OF OWNERIOPERATOR(print): C.SUS/ J2C TITLE OF OWNER/OPERATOR: Division Leader,Operations and Regulatory Affairs Division, 472. <br /> Environmental Protection Department <br /> Permit Number(Agency use only) 473. Permit Approved By(Agency use only) ala. Permit Expiration Date(Agency use only) 475. <br /> 1: <br /> a <br /> UPCF hwfwrc-b(1/99)-3/4 http://www.unidocs.org Rev.02/16/00 <br /> t <br />