Laserfiche WebLink
t'CL OC\ <br /> FIED PROGR&M CNSOLIDATED FO 11 o6 <br /> TANKS <br /> UNDERGROUND STORAGE TANKS -TANK PAGE 1 871-D1U2 <br /> (two pages per tank) <br /> Page l of 2 <br /> TYPE OF ACTION ❑ 1.NEW PERMIT ❑ 4.AMENDED PERMIT ❑ S.CHANGE OF INFORMATION ❑ 6.TEMPORARY TANK CLOSURE 430. <br /> (Check one item only) ❑ 3.RENEWAL PERMIT ❑ 7.PERMANENTLY CLOSED ON SITE <br /> (Specify reason) (Specify reason) ® 8.TANK REMOVED <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As) 3. FACILITY ID: I <br /> Lawrence Livermore National Lab LLNL -Site 300 3q <br /> LOCATION WITHIN SITE(Optional) 431. <br /> North side of Building 871 <br /> I.TANK DESCRIPTION(A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br /> TANK ID# 432• TANK MANUFACTURER 433• COMPARTMENTALIZED TANK ❑Yes ® No 434. <br /> 34 505217 871-D1U2 Modern Welding Co.,Inc. If"Yes,"complete one page for each compartment. <br /> DATE INSTALLED(YEAR/MO) 435• TANK CAPACITY IN GALLONS 436• NUMBER OF COMPARTMENTS 437. <br /> 1994/09 1,000 1 <br /> ADDITIONAL DESCRIPTION(For local use only) 438. <br /> II.TANK CONTENTS <br /> TANK USE 439• PETROLEUM TYPE 440• <br /> N 1. MOTOR VEHICLE FUEL ❑la. REGULAR UNLEADED ❑2. LEADED [15. JET FUEL <br /> (If checked,complete Petroleum Type) ❑lb. PREMIUM UNLEADED ®3. DIESEL ❑6. AVIATION GAS <br /> ❑ 2. NON-FUEL PETROLEUM ❑lc. MIDGRADE UNLEADED ❑4. GASOHOL ❑99.OTHER: <br /> ❑ 3. CHEMICAL PRODUCT COMMON NAME (from Hazardous Materials Inventory page) 441' CAS#(from Hazardous Materials Inventory page) 442. <br /> ❑ 4. HAZARDOUS WASTE Diesel fuel#2 68334-30-5 <br /> (Includes Used Oil) <br /> ❑ 95.UNKNOWN <br /> III.TANK CONSTRUCTION <br /> TYPE OF TANK 0 1. SINGLE WALL D 3. SINGLE WALL WITH EXTERIOR 0 5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443. <br /> (Check one item only) MEMBRANE LINER ❑95. UNKNOWN <br /> ®2. DOUBLE WALL [14. SINGLE WALL IN A VAULT 1:199. OTHER <br /> TANK MATERIAL-primary tank 0 1. BARE STEEL 3. FIBERGLASS/PLASTIC D 5. CONCRETE 0 95.UNKNOWN 444. <br /> (Check one item only) ❑2. STAINLESS STEEL ❑4. STEEL CLAD W/FIBERGLASS ❑8. FRP COMPATIBLE ❑99.OTHER: <br /> REINFORCED PLASTIC FRP W/100%METHANOL <br /> TANK MATERIAL-secondary tank 1. BARE STEEL IN 3. FIBERGLASS/PLASTIC 0 8. FRP COMPTIBLE W/100%METHANOL 0 95.UNKNOWN 445. <br /> (Check one item only) ❑2. STAINLESS STEEL ❑4. STEEL CLAD W/FIBERGLASS ❑9. FRP NON-CORRODABLE JACKET ❑99.OTHER <br /> REINFORCED PLASTIC(FRP) ❑10. COATED STEEL <br /> ❑5. CONCRETE <br /> TANK INTERIOR LINING 1.RUBBER LINED U 3.EPDXY LINING 5.GLASS LINING D 95.UNKNOWN 446. DATE INSTALLED 447. <br /> OR COATING ❑2.ALKYD LINING ❑4.PHENOLIC LINING ®6.UNLINED ❑99.OTHER <br /> Check one item only) <br /> OTHER CORROSION U 1.MANUFACTURED CATHODIC Q 3.FIBERGLASS REINFORCED PLASTIC 0 95.UNKNOWN 448. DATE INSTALLED 449. <br /> PROTECTION PROTECTION ❑4.IMPRESSED CURRENT ❑99.OTHER <br /> If A licable ❑2.SACRIFICIAL ANODE <br /> SPILL AND OVERFILL YEAR INSTALLED 450. TYPE 451. OVERFILL PROTECTION EQUIPMENT: YEAR INSTALLED 452. <br /> (Check all that apply) ®1.SPILL CONTAINMENT _1994 ®1.ALARM 1994 ®3.FILL TUBE SHUT OFF VALVE 1994 <br /> ®2.DROP TUBE _1994 ®2.BALL FLOAT 1994 ❑4.EXEMPT <br /> ®3.STRIKER PLATE 1994 <br /> IV.TANK LEAK DETECTION(A description of the monitoring program shall be submitted to the local agency.) <br /> IF SINGLE WALL TANK (Check all that apply) 453• IF DOUBLE WALL TANK OR TANK WITH BLADDER 454. <br /> (Check one item only) <br /> ❑ 1.VISUAL(EXPOSED PORTION ONLY) ❑5.MANUAL TANK GAUGING(MTG) ❑1.VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑2.AUTOMATIC TANK GAUGING(ATG) ❑6.VADOSE ZONE ®2.CONTINUOUS INTERSTITIAL MONITORING <br /> ❑3.CONTINUOUS ATG ❑7.GROUNDWATER ❑3.MANUAL MONITORING <br /> ❑4.STATISTICAL INVENTORY RECONCILIATION ❑8.TANK TESTING <br /> (SIR)+BIENNIAL TANK TESTING ❑99. OTHER <br /> V.TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/D Y) r 455. ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456. TANK FILLED WITH INERT MATERIAL? 45T <br /> NA-removed,not closed in place t�QS NA-removed,not closed in place gallons_ ❑Yes ❑ No ® NA <br /> nn .,i-on-....:...a{ D..-......1..C{i!D(`O L.......D <br />