My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_FILE 12
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CORRAL HOLLOW
>
15999
>
2300 - Underground Storage Tank Program
>
PR0231945
>
COMPLIANCE INFO_FILE 12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/30/2022 4:43:06 PM
Creation date
6/3/2020 9:55:27 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
FILE 12
RECORD_ID
PR0231945
PE
2361
FACILITY_ID
FA0003934
FACILITY_NAME
Lawrence Livermore National Lab - Site 300
STREET_NUMBER
15999
Direction
W
STREET_NAME
CORRAL HOLLOW
STREET_TYPE
RD
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
15999 W CORRAL HOLLOW RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231945_15999 W CORRAL HOLLOW_FILE 12.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
472
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4. Each product and vapor recovery adaptor shall be 100 percent performance tested <br />at the factory. Each adaptor shall have affixed to it a card or label stating the <br />performance specification listed below and a statement that the adaptor was <br />tested to and met the following specifications. <br />a. The average static torque for the rotatable adaptor shall not exceed 108 <br />pound -inch average static torque when tested in accordance with the latest <br />adopted version of TP -201.1 B, Static Torque of Rotatable Phase I <br />Adaptors. <br />b. The rotatable adaptor shall be capable of rotating at least 360 degrees when <br />tested in accordance with the latest adopted version of TP -201.1 B, Static <br />Torque of Rotatable Phase I Adaptors. <br />Each Spill Container Drain Valve shall be 100 percent performance tested at the <br />factory. Each Spill Container Drain Valve shall have affixed to it a card or label stating <br />the performance specifications listed below and a statement that the valve was tested to <br />and met the following performance specification. <br />a. The maximum leakrate shall not exceed 0.17 CFH at 2.00 inches H2O when tested <br />in accordance with the latest adopted version of either TP -201.1C, Leak Rate of <br />Drop Tube/Drain Valve or TP -201.1 D, Leak Rate of Drop Tube Overfill <br />Prevention Devices and Spill Container Drain Valves. <br />Drop Tube Overfill Prevention Device <br />Each Drop Tube Overfill Prevention Device shall be 100 percent performance tested at <br />the factory to verify that it does not exceed the maximum allowable leak rate. Each <br />Drop Tube Overfill Prevention Device shall have affixed to it a card or label stating the <br />performance specifications listed below and a statement that the device was tested to <br />and met the following performance specification. <br />a. The maximum leak rate shall not exceed 0.17 CFH at 2.00 inches H2O when <br />tested in accordance with the latest adopted version of TP -201.1 D, Leak Rate of <br />Drop Tube Overfill Prevention Devices and Spill Container Drain Valves. <br />Executive Order VR -102-E, OPW Phase I Vapor Recovery System, Exhibit 3, Page 2 <br />