Laserfiche WebLink
.01/28/05 16:13 FAX 925 422 2748 EPD / WGMG 1j003 <br />SWRCB, January 2002 FINAL DRAIFT Page I of <br />Secondary Containment Testing Report Form <br />This form is intended for use by contractors performing periodic testing of UST secondary containment systems. Use the <br />appropriate pages of this form to report results for all components tested. The completed form, mitten test procedures, and <br />printouts from tests (if applicable), should be provided to the facility ownerloperatorfor submittal to the local regulatory agency. <br />1. FACILITY INFORMATION <br />Facility Name: Lawrence Livermore National Laboratory Site 300 882 -Dr 1A 1] Date of Testing: 12-28-2005"o// <br />-Facility Address: Corral Hollow Road, Tracy, CA 95376 - <br />-Facility Contact: Shari Brigdon - - I Phone: (925) 423-7465 <br />-Date Local Agency was Notified of Testing: 12-23-20DTt,,>+ <br />Name of Local Agency Inspector (if present during testing): <br />Name: <br />Thornton Environmental Construction, Inc. <br />-Company <br />Technician Conducting Test: Brian Thornton <br />Credentials: <br />0 CSLB Licensed Contractor E] SWRCB Licensed Tank Tester <br />License Type: A, C-10; HAZ 7 License Number: 724513 <br />Manufacturer <br />Manufacturer Training <br />Component <br />Date Training Expires <br />Veeder-Root <br />Leak Monitor <br />06-10-2005 <br />Ronan <br />Leak Monitor <br />12-13-2005 <br />USD Leak Alert <br />Leak Monitor <br />11-01-2005 <br />Caldwell <br />Sump Level Change Indicator. <br />One time training <br />Comments - If hydrostatic testing was performed, describe what was done with the water after completion of test(s). <br />-Test water was left on site in customers 55 gallon DOT drums for disposal by customer. <br />CERTIFICATION 05 TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING <br />To the best of my knowledge, the facts stated in this document are accurate and in full compliance with legal requirements. <br />Technician's Name (Please Print): Brian Thornton <br />Technician's Signature: _Z2 <br />Date: 12-29-201" <br />Component <br />Em <br />NMI <br />DIESEL TANK ANNULAR <br />IL <br />DIESEL PIPING SUMP <br />F*S/ FOR CONTAINMEN <br />"M <br />MEN <br />0E <br />MOM <br />E <br />Comments - If hydrostatic testing was performed, describe what was done with the water after completion of test(s). <br />-Test water was left on site in customers 55 gallon DOT drums for disposal by customer. <br />CERTIFICATION 05 TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING <br />To the best of my knowledge, the facts stated in this document are accurate and in full compliance with legal requirements. <br />Technician's Name (Please Print): Brian Thornton <br />Technician's Signature: _Z2 <br />Date: 12-29-201" <br />