Laserfiche WebLink
UNIFIED PROGRAM CONSOLIDATED FORM-TANKS <br /> UNDERGROUND STORAGE TANKS-TANK PAGE 2 els-ca�1 wsklco5115 <br /> _ Pa e?of 2 <br /> ----._...__....._v <br /> VI.PIPING CONSTRUCTION(Check aiiihat apply) <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SYSTEM TYPE ®1.PRESSURE SPLY ❑2.SUCTION ®3.GRAVITY nTN 458. ❑1.PRDSSURL ❑2.SUCTION ❑3.GRAVITY 4% <br /> CONSTRUCTION/ ❑1.SINGLE WALL ❑3.LINED TRENCH ❑99.OTHER 460 ❑1 SINGLE WALL ❑95.UNKNOWN 462, <br /> MANUFACTURER <br /> ®2.DOUBLE WALL ❑95.UNKNOWN ❑2.DOUBLE WALL ❑99.OTHER <br /> MANUFACTURER steel/Ameron-FRP 461. MANUFACTURER 463. <br /> ®1.BARE STEEL ❑6.FRP COMPATIBLE W1100%METHANOL ❑1.BARE STEEL ❑6.FRP COMPATIBLE WI100%METHANOL <br /> ❑2.SIAINLESS STEEL ❑7.GALVANIZED STEEL ❑2.STAINLESS STEEL ❑7.GALVANIZED STEEL <br /> ❑3,PLASTIC COMPATIBLE WITH CONTENTS ❑95.UNKNOWN ❑3.PLASTIC COMPATIBLE W1 CONTENTS ❑8.FLEXIBLE(HDPE) ❑99.OTHER <br /> ®4 FIBERGLASS ❑8.FLEXIBLE(HDPE) ❑99.OTHER ❑4.FIBERGLASS ❑9 CATHODIC PROTECTION <br /> ❑5.STEEL W/COATING ❑9.CATHODIC PROTECTION 464. ❑5 STEEL WICOATING ❑95.UNKNOWN 465. <br /> VII.PIPING LEAK DETECTION(Check all that apply)(A description of the monilodng program shall be submitted to the local agency.) <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SINGLE WALL PIPING 466 SINGLE WALL PIPING 467. <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply). <br /> ❑1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUTOFF FOR ❑I. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF FOR <br /> LEAK, SYSTEM FAILURE, AND SYSTEM DISCONNECTION +AUDIBLE AND VISUAL LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND VISUAL <br /> ALARMS. ALARMS. <br /> ❑2. MONTHLY 0.2 GPH TEST ❑2 MONTHLY 0.2 GPH TEST <br /> ❑3. ANNUAL INTEGRITY TEST(0.1 GPH) ❑3. ANNUAL INTEGRITY TES1(0.1 GPH) <br /> ❑4. DAILY VISUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS CONVENTIONAL SUCTION SYSTEMS(Check all that apply) <br /> ❑5. DAILY VISUAL MONITORING OF PUMPING SYSTEM+TRIENNIAL PIPING INTEGRITY [35. DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> TEST(0.1 GPH) <br /> SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): ❑6. TRIENNIAL INTEGRITY TEST(0.1 GPH) <br /> ❑7. SELF MONITORING SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING) <br /> GRAVITY FLOW ❑7. SELF MONITORING <br /> [19. BIENNIAL INTEGRITY TEST(0.1 GPH) GRAVITY FLOW(Check all that apply): <br /> ❑8. DAILY VISUAL MONITORING <br /> ❑9. BIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SECONDARILY CONTAINED PIPING SECONDARILY CONTAINED PIPING <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> 10.CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE&VISUAL ALARMS AND(Check one) 10.CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE&VISUAL ALARMS AND(Check one) <br /> ®a.AUTO PUMP SHUT OFF WHEN A LEAK OCCURS ❑a.AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> ❑b.AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE,&SYSTEM DISCONNECTION ❑b.AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE&SYSTEM DISCONNECTION <br /> ❑c.NO AUTO PUMP SHUT OFF ❑C.NO AUTO PUMP SHUT OFF <br /> ®11.AUTOMATIC LINE LEAK DETECTOR(3.0 GPIs TEST)WITH FLOW SHUT OFF OR <br /> RESTRICTION ❑11.AUTOMATIC LEAK DETECTOR <br /> Ll 12.ANNUAL INTEGRITY TEST(0.1 GPH) ❑12.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> SUCTIONIGRAVITY SYSTEM SUCTIONIGRAVITY SYSTEM <br /> ❑13.CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS ❑13.CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS <br /> EMERGENCY GENERATORS ONLY(Check all that apply) EMERGENCY GENERATORS ONLY(Check all that apply) <br /> ❑14.CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF+AUDIBLE&VISUAL ❑14.CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF*AUDIBLE&VISUAL <br /> ALARMS ALARMS <br /> ❑15.AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITHOUT FLOW SHUT OFF OR <br /> RESTRICTION ❑15 AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST) <br /> ❑16.ANNUAL INTEGRITY TEST(0.1 GPH) [116.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑17.DAILY VISUAL.CHECK ❑17.DAILY VISUAL CHECK <br /> VIII.DISPENSER CONTAINMENT <br /> DISPENSER CONTAINMENT 466. ®1.FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE ❑4.DAILY VISUAL CHECK 469. <br /> DATE INSTALLED ❑2.CONTINUOUS DISPENSER PAN SENSOR-AUDIBLE AND VISUAL ALARMS ❑5.TRENCH/LINER MONITORING <br /> June 1994 ❑3.CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR DISPENSER-AUDIBLE&VISUAL ALARMS ❑6.NONE <br /> IX.OWNERIOPERATOR SIGNATURE <br /> I certify that the information provided herein is true and accurate to the best of my knowledge. <br /> SIGNATURE OF OWNERIOPE OR <br /> DATE: 470. <br /> NAME OF OWNER/OPERATOR(print): C.SUSI Jacksij TITLE OF OWNER/OPERATOR: Division Leader,Operations and Regulatory Affairs Division, 472 <br /> Environmental Protection Department <br /> Permit Number(Agency use only) 473. 1 Permit Approved By(Agency use only) 474. 1 Permit Expiration Date(Agency use only) 475. <br /> UPCF hwfwrc-b(1/99)-3/4 http://www.unidocs.org Rev.02/16/00 <br />