COMPLIANCE INFO_FILE 12
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CORRAL HOLLOW
>
15999
>
2300 - Underground Storage Tank Program
>
PR0231945
>
COMPLIANCE INFO_FILE 12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/30/2022 4:43:06 PM
Creation date
6/3/2020 9:55:27 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
FILE 12
RECORD_ID
PR0231945
PE
2361
FACILITY_ID
FA0003934
FACILITY_NAME
Lawrence Livermore National Lab - Site 300
STREET_NUMBER
15999
Direction
W
STREET_NAME
CORRAL HOLLOW
STREET_TYPE
RD
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
15999 W CORRAL HOLLOW RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231945_15999 W CORRAL HOLLOW_FILE 12.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
472
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNIFIED PROGRAM CONSOLIDATED FORM TANKS <br /> UNDERGROUND STORAGE TANKS -TANK PAGE 2 892-DIUI WGMG03:145 <br /> Vl. PIPING CONSTRUCTION(Check all that apply) Page-2,of,Z <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SYSTEM TYPE, ❑1.PRESSURE ®2.SUCTION-FOS ®3.GRAVITY-FOR 458 ❑1.PRESSURE ®2.SUCTION-FOS ®3.GRAVITY-FOR 459 <br /> CONSTRUCTION1 ❑1.SINGLE WALL ❑3.LINED TRENCH ❑99.OTHER 460 ®1.SINGLE WALL ❑95.UNKNOWN 462 <br /> MANUFACTURER®2.DOUBLE WALL ❑95.UNKNOWN ❑2.DOUBLE WALL ❑99.OTHER <br /> MANUFACTURER:Primary:US Steel/Black Iron Secondary.Ameron Dualoy 30M/L FRP 461 MANUFACTURER.Primary:Unkno-/Black Iron 463 <br /> ®L BARE STEEL-Pri ❑6.FRP COMPATIBLE W/100`/.METHANOL M I BARE STEEL-Pri ❑6 F KP COMPAl7BLE W/100%.METHANOL <br /> ❑2.STAINLESS STEEL ❑7.GALVANIZED STEEL ❑95.UNKNOWN ❑2 STAINLESS STEEL ❑7.GALVANIZED STEEL ❑95.UNKNOWN' <br /> ❑3.PLASTIC COMPATIBLE W/CONTENTS ❑99 OTHER ❑3.PLASTIC COMPATIBLE W(CONTENTS ❑99.OTHER <br /> ®4 FIBERGLASS-Sec ❑8 FLEXIBLE(HDPE) ❑4 FIBERGLASS ❑s.FLEXIBLE(HDPE) <br /> ❑5 STEEL W/COATING ❑9.CATHODIC PROTECTION 464 ❑5.STEEL W/COATING ❑9.CATHODIC PROTECTION 465 <br /> VII. PIPING LEAK DETECTION(Check all that a v)(A descrition of the monitoring program shall he submitted to the local agency <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SINGLE WALL PIPING 466 SINGLE:WALL PIPING 467 <br /> Note:Emergency Generator:Monthly ins, ti ms.AG piping excluder)per H&S Cnde 252R 15(bx3) <br /> PRESSURIZED PIPING(Check all that apply) PRESSURIZED PIPING(Check all that apply) <br /> ❑1.ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT ❑1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WW I_I HH AUTO PUMP <br /> OFF FOR LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION+ SHUT OFF FOR LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION+ <br /> AUDIBLE AND VISUAL ALARMS, AUDIBLE AND VISUAL ALARMS. <br /> ❑2.MONTHLY 0.2 GPH TEST ❑2. MONTHLY 0.2 GPH TEST <br /> ❑3.ANNUAL INTEGRITY TEST RIGPH) ❑3.ANNUAL INTEGRITY TEST(0.1GPH) <br /> ❑4. DAILY VISUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS CONVENTIONAL SUCTION SYSTEMS(Check all that apply) <br /> ❑5.DAILY VISUAL MONITORING OF PUMPING SYSTEM,TRIENNIAL PIPING ❑5. DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> INTEGRITY TEST(0.1 GPH) <br /> ❑6. TRIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SAFE SUCTION SYSTEMS(NO VALUES IN BELOW GROUND PIPING) SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING) <br /> ❑7.SELF MONITORING ❑T SELF MONITORING <br /> GRAVITY FLOW GRAVITY FLOW(Check all that apply) <br /> ❑9.BIENNIAL INTEGRITY TEST(0.1 GPH) ❑8. DAILY VISUAL MONITORING <br /> ❑9. BIENNIAL INTEGRITY TEST(0 1 GPH) <br /> SECONDARILY CONTAINED PIPING SECONDARILY CONTAINED PIPING <br /> PRESSURIZED PIPING(Check all that apply) PRESSURIZED PIPING(Check all that apply) <br /> 10.CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL 10.CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL <br /> ALARMS AND(Check one) ALARMS AND(Cheek one) <br /> ❑a.AUTO PUMP SHUT OFF WHEN A LEAK OCCURS ❑a.AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> ❑It.AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM ❑It.AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM <br /> DISCONNECTION DISCONNECTION <br /> ❑c.NO AUTO PUMP SHUT OFF ❑C.NO AUTO PUMP SHUT OFF <br /> ❑11.AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)_WITTI FLOW SHUT ❑11.AUTOMATIC LEAK DETECTOR <br /> OFF OR RESTRICTION <br /> ❑12.ANNUAL INTEGRITY TEST(0.1 GPH) ❑12.ANNUAL INTEGRITY TEST(0 1 GPH) <br /> SUCTION/GRAVITY SYSTEM SUCTION/GRAVITY SYSTEM <br /> ❑13.CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS ❑13.CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS <br /> EMERGENCY GENERATORS ONLY(Check all that apply) EMERGENCY GENERATORS ONLY(Check all that apply) <br /> ®14.CONTINUOUS SUMP SENSOR WITH AUTO PUMP SHUT OFF+ ❑14.CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF+ <br /> AUDIBLE AND VISUAL ALARMS AUDIBLE AND VISUAL ALARMS <br /> ❑15.AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITHOUT FLOW ❑15.AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST) <br /> SHUT OFF OR RESTRICTION <br /> ❑16.ANNUAL INTEGRITY TEST(0.1 GPH) ❑16.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑17.DAILY VISUAL CHECK ❑17.DAILY VISUAL CHECK <br /> V111. DISPENSER CONTAINMENT <br /> DISPENSER CONTAINMENT ❑1.FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE ❑4.DAILY VISUAL CHECK <br /> DATE INSTALLED 468 ❑2.CONTTNI)OI 1S DISPFNSF,R PAN SENSOR+AUDIBLE AND VISUAL ALARMS ❑5.TRENCH LINER/MONITORING <br /> NA ❑3.CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR ®6.NONE 469 <br /> DISPENSER+AUDIBLE AND VISUAL ALARMS <br /> ER/OPERATOR SIGNATURE <br /> I certify that the.information provided herein is we and accurate two th LK <br /> SIGNATURE OF OWNER/OPERATOR DATE 470 <br /> 10"M003 3 <br /> NAME OF OWNER/OPERATOR(print) r 1 471 TITLE OF OWNER/OPERATOR 472 <br /> William G.Hoppes Crca,p Leader,Water Guidance and Moniwring Group,Environmental Protection Deportment <br /> Permit Number(For local use only) 473 Permit.Approved(For local use ally) 474 Permit Fxpiration Date(For local use only) 475 <br /> UPCF(12/99 revised) Formerly SWRCB Form B <br />
The URL can be used to link to this page
Your browser does not support the video tag.