Laserfiche WebLink
MINIMUM VERIFICATION LABORATORY ANALYSIS nnrrss <br /> TANK TANK TPH-3 TFH7 BTX& CL HC TOTAL EDB METALS PCB <br /> # CONTENTS 8015 8015 E 8010 LEAD ICAP/ 8270 <br /> 8260 8260 8020 8244 7420 8240 AES or 8080 <br /> 8260 7421 AA <br /> 11879- LEADED GAS X X X X <br /> 1 GIU1 <br /> UNL GAS X X <br /> DIESEL X X <br /> KEROSENE X X <br /> UrNX FT.TEL. X X X X X <br /> PROD OIL X X <br /> CHLOR. X X <br /> SOLL'E_N TS <br /> NONCHLOR X X X <br /> SOLVENTS <br /> W ASTE\ X —t X X X X X <br /> USED OIL <br /> All analyses methods are designated EPA methods described in EPA SW W.Third Edition. Those methods not found in <br /> SW 846,are specifically noted below. Refer to the"SWRCB LUFT Field Manual".Appendix A-20.Table 3-5 for detection <br /> limits of motor vehicle fuels(gasoline and diesel). Refer to 1-2-3"Regional Board Staff Recommendations for Initial <br /> Evaluation and Investigation of UST's"for the waste and motor oil detection limits. <br /> Detection Limits that remain below the MCL. STLC or Allowabk Limit of the contaminant in <br /> question will be accepted, however laboratory shall utilize the most conservative method. <br /> LABORATORY ANALYSES TERMINOLOGY: <br /> TPH-G Total Petroleum Hydrocarbon.Gasoline.GC/FID(5030)8015 mod or GC/MS 8260 <br /> TPH-D Total Petroleum Hydrocarb a.Diesel.GGE�(3550).8015 mod or GC/MS 8260 <br /> BTX&E Benzene.Toluene.Xylene&Ethyl Benzene,GC/PID 8020 or GC/MS 8260 <br /> CL HC Chlorinated Hydrocarbon.GC/HSD 8010,GC/MS 8240 <br /> TOTAL LEAD Total lead.AA 7420, AA 7421 or ICP-AES 6010 <br /> EDB Ethylene dibromide(DISC-AB 18031,GCIMS 8240(DTSC-LUFT) <br /> GC-FID Gas Chromatography,Flame Ionization Detection <br /> ICAP or AA Inductively Coupled Plasma Atomic Emission Spectrometry 6010 or Atomic Absorption <br /> Spectrometry 7000. Metals: Cadmium, Chromium III and VI, Lead, Zinc and Nickel. <br /> PCB Polychlorinated Biphenyls.GC/MS 8270 or 8080 <br /> Method 3050 Acid digestion <br /> Method 3540 Soxhlet sample.preparation <br /> Method 3550 Sonication sample preparation.extraction method <br /> Method 5030 Purge and trap sample preparation <br /> QA/QC Quality Assurance/Quality Contml <br /> Notes: To avoid false positive detection of benzene.benzene-free solvents are to be used. Fused capillary columns are <br /> preferred to packed cohratns:a packed column may be used as a"first cut"with"dirty"samples or once the hydrocarbons have <br /> teen characterized and proptr QA/AC is followed. <br /> For Drinking water sources,EPA recommends that the 500 series for volatile organics be used in preference to the 600 series <br /> because the detection limits are lower and the QA/QC is better. Samples exhibiting any level of heavy metal contamination <br /> may require further analysis. PHS-EHD recommends huldin=these samples until disposal is indicated. <br /> EH 23 048 (Rev 7/10/92) <br /> 8 . <br />