Laserfiche WebLink
CLOSURE REPORT FOR UNDERGROUND STORAGE TANKS 879-GlU1&879-G2U1 <br /> ENVIRONMENTAL SAMPLE INFORMATION: <br /> SOIL <br /> Soil sample collection and handling procedures were in accordance with LLNL Tank <br /> Assessments and Guidance Group Procedure 203,Soil Sampling. <br /> Soil samples were collected by: Dave Castro&Steve Trainque,LLNL Date: 3/28&30/94 <br /> Sample analyses requested: Tank Excavation (TPH Diesel and BTXE)Stockpile (TPH Diesel; <br /> BTXE; 8010/8020, Metals by STLC and TTLC; and Reactivity, Corrosivity, and Ignitability <br /> (RCI))•and Buildings 827,836,and 879 tank removal stockpiles composited for gross alpha& <br /> beta tritium, and gamma spectrometryL(samples collected for disposal options). Samples <br /> collected for disposal options included 1 discrete sample collected for each 25 yards. <br /> TPH-D•Total Petroleum HTdro6rbons as Diesel• BTXE: Benzene Toluene Xylenes and Ethyl Benzene; <br /> HVOC• EPA Method 8010 for Halogenated Volatile Organic Carbons• AVOC• EPA Method 8020 for Aromatic Volatile Organic <br /> Carbons STT C• Soluble Threshold Lin-3t Concentration; TTLC•Total Threshold Limit Concentration <br /> Name and address of analytical laboratory: California Laboratory Services, 3249 Fitzgerald <br /> Road Rancho Cordova CA 95742. [Radiological analyses on stockpile composite samples <br /> were performed by LLNL Environmental-Analytical Sciences Lab]. <br /> Describe how the tank excavation was secured after soil sample collection: The excavation was <br /> secured by means ofely low plastic "snow fence" and barricades equipped with flashing <br /> lights Later, the excavation was backfilled with imported clean fill (pea gravel) after <br /> installation of UST 879-G3U1. <br /> WATER <br /> [ ] Not applicable. (No water in the tank excavation or piping trench) <br /> Static water level below grade: N A feet <br /> Describe any sheen,free product or odor present in the water: None present. <br /> Water pumped out of the excavation: [X]Yes [ ]No <br /> Volume of water removed from the tank excavation: 5,000 gallons* <br /> *Note:Initially reported as 3,000-gallons in UST Unauthorized Leak Report. <br /> Water sampled: [X]Yes [ ]No <br /> Water sample was collected by: Toe Woods(LLNL-Environmental Operations Group)Date:3/17/94 <br /> Sample analyses requested: BTXE values were less than 1 µg/L,except for Toluene at 3 gg/L. <br /> Name and address of analytical laboratory: Environmental Analytical Sciences, Lawrence <br /> Livermore National Laboratory Livermore CA 94551 <br /> Describe how the water was sampled: Sampling container (500 mL amber jar) was submerged <br /> into the water within the tank excavation and used to fill 2 Volatile Organic Analysis (VOA) <br /> bottles allowing for a positive meniscus or no head space),and then filling two 500 mL amber <br /> jars All samples were submitted immediately for analysis. <br /> Identify the source of the water(if known): During initial excavation of UST 879-G1U1 &-G2U1 <br /> ,(3/17/94) breakage of the on-site water distribution and supply system to Building 879 <br /> (Site 300 Water Main)occurred <br /> Describe where and how the removed water was stored on site, and type of containment used: <br /> Erickson pumped 5.000-gallons of water from the excavation into their truck. The <br /> Underground Storage Tank Unauthorized (Leak)/Contamination Site Report for the Water <br /> Release in Closure Excavation of Tanks 879-GlU1 and 879-G2U1 is enclosed as Appendix D. <br /> Water Disposal Information: <br /> [ ] Not Applicable. (Water not encountered,or not disposed of as hazardous waste) <br /> The water was transported by: Erickson Inc (Hauler Registration No. 0019), 255 Parr Blvd., <br /> Richmond CA 94801 (510-235-1393• David Sato Supervisor). <br /> The water was disposed of as: Non-hazardous Liquid(Approx.5,000 gal.) Date: 4/8/94 <br /> Name and address of disposal facility: Gibson Oil & Refining Company, Inc., 330 Truxtun <br /> Avenue Suite 200 Bakersfield CA 93301 <br /> [ X ] LLNL letter (dated 4/7/94) for the "Disposal of Non-hazardous Liquid" and attached <br /> Gibson Liquid Waste Profile Sheet copy for the water is enclosed as Appendix D. <br /> 3 <br />