Laserfiche WebLink
MINIMUM VERIFICATION LABORATORY ANALYSIS 0W281. <br /> TANK TANK TPH-G TPH-D BTX& CL HC TOTAL EDB METALS PCB <br /> x CONTENTS 8015 8015 E 8010 LEAD ICRP/ 8270 <br /> 8260 8260 8020 8240 7420 8240 AES or 8080 <br /> 8260 7421 AA <br /> GAS X X X X <br /> UNL GAS X X <br /> 827- DIESEL X X <br /> D2U1 <br /> KEROSENE X X X X <br /> UNK FUEL X X X <br /> PROD.OIL X X <br /> CHLOR. X X <br /> SOLVENTS <br /> IN— ONCHI.OR X X X <br /> OLVEN'T'S X X X <br /> WASTE\ X X X <br /> USED OIL <br /> All analyses methods are designated EPA methods described in EPA SW 846,Third Edition. Those methods not found in <br /> SW 846,are specifically noted below. Refer to the"SWRCB LUFT Field Manual",Appendix A-20,Table 3-5 for detection <br /> limits of motor vehicle fuels(gasoline and diesel). Refer to 1-2-3"Regional Board Staff Recommendations for Initial <br /> Evaluation and Investigation of USTs"for the waste and motor oil detection limits. <br /> Detection Limits that remain below the MCL; STLC or Allowable Limit of the contaminant in <br /> question will be accepted, however laboratory shall utilize the most conservative method.- <br /> LABORATORY <br /> ethod.-LABORATORY ANALYSES TERMINOLOGY: <br /> C_ TPH-G Total Petroleum Hydrocarbon,Gasoline,GC/FID(5030)8015 mod or CIMSGCIM60 TPH-D Total Petroleum Hydrocarbon,Diesel,GC/FID(3550),8015 mod o<GC/MS 8260 <br /> BTX&E Benzene,Toluene,Xylene&Ethyl Benzene,GC/PID 8020 or GC/MS 8260 <br /> CL HC Chlorinated Hydrocarbon,GC/HSD 8010,GC/MS 8240 <br /> TOTAL LEAD Total lead,AA 7420, AA 7421 or ICP-AES 6010 <br /> EDB Ethylene dibromide(DTSC-AB 1803),GC/MS 8240(DISC-LUFI) <br /> GC-FID Gas Chromatography,Flame Ionization Detection <br /> ICAP or AA Inductively Coupled Plasma Atomic Emission Spectrometry 6010 or Atomic Absorption <br /> Spectrometry 7000. Metals: Cadmium, Chromium III and VI, Lead, Zinc and Nickel. <br /> PCB Polychlorinated Biphenyls,GC/MS 8270 or 8080 <br /> Method 3050 Acid digestion <br /> Method 3540 Soxhlet sample preparation <br /> Method 3550 Sonication sample preparation,extraction method <br /> Method 5030 Purge and trap sample preparation <br /> QAC Quality Assurance/Quality Control <br /> Notes: To avoid false positive detection of benzene,benzene-free solvents are to be used. Fused capillary columns are <br /> preferred to packed columns;a packed column may be used as a"fust cut"with"dirty"samples or once the hydrocarbons have <br /> been characterized and proper QA/AC is followed. <br /> For Drinking water sources,EPA recommends that the 500 series for volatile organics be used in preference to the 600 series <br /> because the detection limits are lower and the QA/'QC is better. Samples exhibiting any level of heavy metal contamination <br /> may require further analysis. PHS-EHD recommends holding these samples until disposal is indicated <br /> EH 23 048(Rev 7/10/92) <br /> 8 <br />