Laserfiche WebLink
4 FIED PROGRAM CONSOLIDATED FW <br />TANKS <br />UNDERGROUND STORAGE TANKS - TANK PAGE 1 <br />(two pages per tank) <br />Page _of <br />TYPE OF ACTION ❑ 1 NEW SITE PERMIT ❑ 4 AMENDED PERMIT ® 5 CHANGE OF INFORMATION ❑ 6 TEMPORARY SITE CLOSURE <br />(Check one item only) ❑ 7 PERMANENTLY CLOSED ON SITE <br />❑ 3 RENEWAL PERMIT (Specify reason - for local use only) (Specify reason - for local use only) ❑ 8 TANK REMOVED 430 <br />BUSINESS NAME (Same as FACILITY NAME or DBA - Doing Business As) <br />FACILITY ID: <br />1 <br />Circle K # 2705446 <br />3 <br />LOCATION WITHIN SITE (Optional) 431 <br />I. TANK DESCRIPTION (A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br />TANK ID # 432 <br />TANK MANUFACTURER 433 <br />COMPARTMENTALIZED TANK ❑ Yes ® No 434 <br />1 <br />Owens Corning <br />tf"Yes",complete one page foreach compartment. <br />DATE INSTALLED (YEAR/MO) 435 <br />TANK CAPACITY IN GALLONS 436 <br />NUMBER OF COMPARTMENTS 437 <br />1991 <br />12,000 <br />ADDITIONAL DESCRIPTION (For local use only) 438 <br />II. TANK CONTENTS <br />TANK USE 439 <br />PETROLEUM TYPE 440 <br />® 1. MOTOR VEHICLE FUEL <br />® ]a. REGULAR UNLEADED ❑ 2. LEADED ❑ 5. JET FUEL <br />(If marked complete Petroleum Type) <br />❑ 1 b. PREMIUM UNLEADED ❑ 3. DIESEL ❑ 6. AVIATION FUEL <br />❑ 2. NON -FUEL PETROLEUM <br />❑ Ic. MIDGRADE UNLEADED ❑ 4. GASOHOL ❑ 99. OTHER <br />❑ 3. CHEMICAL PRODUCT <br />COMMON NAME (from Hazardous Materials Inventory page) 441 <br />CAS# (from Hazardous Materials Inventory page) 442 <br />❑ 4. HAZARDOUS WASTE <br />(Includes Used Oil) <br />❑ 95. UNKNOWN <br />III. TANK CONSTRUCTION <br />TYPE OF TANK ❑ 1. SINGLE WALL ❑ 3. SINGLE WALL WITH ❑ 5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br />(Check one item only) EXTERIOR MEMBRANE LINER ❑ 95. UNKNOWN <br />® 2. DOUBLE WALL ❑ 4. SIGNLE WALL IN VAULT ❑ 99. OTHER ..... <br />TANK MATERIAL - primary tank ❑ 1. BARE STEEL 03. FIBERGLASS / PLASTIC ❑ 5. CONCRETE ❑ 95. UNKNOWN 444 <br />(Check one item only) ❑ 2. STAINLESS STEEL ❑ 4. STEEL CLAD W/FIBERGLASS ❑ 8. FRP COMPTIBLE W/100% METHANOL ❑ 99. OTHER ..... <br />REINFORCED PLASTIC (FRP) <br />TANK MATERIAL - secondary tank ❑ 1. BARE STEEL ® 3. FIBERGLASS/ PLASTIC ❑ 5. CONCRETE ❑ 95. UNKNOWN 445 <br />(Check one item only) ❑ 2. STAINLESS STEEL ❑ 4. STEEL CLAD W/FIBERGLASS [J8. FRP COMPTIBLE W/100% METHANOL ❑ 99. OTHER ..... <br />REINFORCED PLASTIC (FRP) ❑ 10. COATED STEEL <br />❑ 5. CONCRETE <br />TANK INTERIOR LINING ❑ I. RUBBER LINED ❑ 3. EPDXY LINING ❑ 5. GLASS LINING ❑ 95. UNKNOWN 446 DATE INSTALLED 447 <br />OR COATING ❑ 2 ALKYD LINING ❑ 4 PHENOLIC LINING ❑ 6 UNLINED ❑ 99 OTHER ..... <br />For local use only) <br />(Check one item only) ( y) <br />OTHER CORROSION ❑ 1 MANUFACTURED CATHODIC ❑ 3 FIBERGLASS REINFORCED PLASTIC ❑ 95 UNKNOWN 448 448 <br />PROTECTION IF APPLICABLE PROTECTION ❑ 4 IMPRESSED CURRENT ❑ 99 OTHER <br />(Check one item only) ❑ 2 SACRIFICIAL ANODE (For local use only) <br />SPILL AND OVERFILL YEAR INSTALLED 450 TYPE (local use only) 451 <br />OVERFILL PROTECTION EQUIPMENTNEAR INSTALLED 452 <br />(Check all that apply) ® 1 SPILL CONTAINMENT 2003 _ _ _ _ _ <br />® 1 ALARM Unk ❑ 3 FILL TUBE SHUT OFF VALVE <br />® 2 DROP TUBE 2003 _ _ _ _ _ <br />® 2 BALL FLOAT 2003 ❑ 4 EXEMPT <br />® 3 STRIKER PLATE Unk <br />IV. TANK LEAK DETECTION (A description of the monitoring program shall be submitted to the local agency.) <br />IF SINGLE WALL TANK (Check all that apply) 453 <br />IF DOUBLE WALL TANK OR TANK WITH BLADDER 454 <br />(Check one item only) <br />p 1 VISUAL (EXPOSED PORTION ONLY) ❑ 5 MANUAL TANK GAUGING (MTG) <br />❑ 1 VISUAL (SINGLE WALL IN VAULT ONLY) <br />❑ 2 AUTOMATIC TANK GAUGING (ATG) ❑ 6 VADOSE ZONE <br />® 2 CONTINUOUS INTERSTITIAL MONITORING <br />❑ 3 CONTINUOUS ATG ❑ 7 GROUNDWATER <br />❑ 3 MANUAL MONITORING <br />❑ 4 STATISTICAL INVENTORY RECONCILIATION ❑ 8 TANK TESTING <br />(SIR) BIENNIAL TANK TESTING ❑ 99 OTHER ----- <br />____IV. <br />IV. TANK CLOSURE INFORMATION / PERMANENT <br />CLOSURE IN PLACE <br />ESTIMATED DATE LAST USED (YR/MO/DAY) 455 <br />ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456 <br />TA NK FILLED WITH INERT MATERIAL? 457 <br />gallons <br />[]Yes ❑ No <br />UPCF (1/99 revised) 173 Formerly SWRCB Form B <br />