COMPLIANCE INFO_2009-2010
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COUNTRY CLUB
>
1403
>
2300 - Underground Storage Tank Program
>
PR0231995
>
COMPLIANCE INFO_2009-2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/18/2023 11:36:29 AM
Creation date
6/3/2020 9:56:17 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2010
RECORD_ID
PR0231995
PE
2361
FACILITY_ID
FA0006438
FACILITY_NAME
United # 5446
STREET_NUMBER
1403
Direction
W
STREET_NAME
COUNTRY CLUB
STREET_TYPE
BLVD
City
STOCKTON
Zip
95204
APN
12323246
CURRENT_STATUS
01
SITE_LOCATION
1403 W COUNTRY CLUB BLVD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231995_1403 W COUNTRY CLUB_2009-2010.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
359
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
is Is Page 2. <br />SVJRCBn, January 2002 <br />6. PIPING SUMP TESTING <br />Test Method Developed By: ❑ Sump Manufacturer ❑X Industry Standard ❑ Professional Engineer <br />El Other (Specify) <br />Test Method Used: <br />Pressure ❑ Vacuum ❑X Hydrostatic <br />Other (Specify) <br />Test Equipment Used: vplt Equipment Resolution: <br />Sump # 1 DIE Sump # 2 REG Sump # 3 SUP Sump # <br />Sump Diameter: 4811 4 8" 4811 <br />Sump Depth: <br />7211 <br />7211 7211 <br />Sump Material: <br />fiberglass <br />fiberglass fiberglass <br />Height from Tank Top to Top of <br />2811 <br />28" 2811 <br />Highest Piping Pentration: <br />Height from Tank Top to Lowest <br />3711 <br />37" 3711 <br />Electrical Pentration: <br />Condition of sump prior to testing: <br />good <br />good good <br />Portion of Sump Tested: 1 <br />3011 <br />3 0 ff 3011 <br />Does turbine shut down when <br />sump sensor detects liquid (both <br />X❑Yes ❑No[:]N <br />ayes EINCIN 'Yes ❑NoE]N ❑Yes ❑No❑N <br />product and water)?* <br />Turbine shutdown response time: <br />2-5 secs <br />2-5 secs 2-5 sec s <br />Is system programmed for fail-safe---'Yes <br />X Yes N N <br />❑ <br />Yes N N X Yes N N X Yes No <br />shutdown?* <br />L�jX <br />Was fail-safe verified to be <br />X Yes N N <br />❑ ❑ <br />X Yes N N X Yes N N r-1-1 <br />Yes No <br />operational?* <br />Wait time between applying <br />pressure/vacuum/water and starting <br />5 min <br />5 min 5 min <br />test: <br />Test Start Time: <br />7:18 <br />7:24 8 : 59 <br />Initial Reading (RI ): <br />2.289 <br />7.488 5.837 <br />Test End Time: <br />7:48 <br />7: 54 9:2 9 <br />Final Reading (RF ): <br />1.937 <br />7.392 5.837 <br />Test Duration: <br />3 0 min <br />30 min 3 0 min <br />Change in Reading (RF- RI ): <br />. 028gph <br />. 007gph . 000gph <br />Pass/Fail Threshold or Criteria: <br />. 05gph <br />. 05gph . 05gph <br />Was sensor removed for testing? <br />X YesENoEINA <br />X Ye N NA X YesON NA Yes ONo <br />Was sensor properly replaced and <br />❑ N�NA❑ <br />XYe <br />X ® <br />Ye� N� NA❑Ye�N�NA es❑ N`EIN <br />verified functional after testing? <br />Comments - (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />starting and ending values are taken off the VPLT an2l used to ca u ate the GPH <br />1 If the entire depth of the sump is not tested, specify how much was tested. If the answer to my of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />