Laserfiche WebLink
ONIT NG SYSTEM CERTIRCATION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be <br /> prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to <br /> the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems <br /> within 30 days of test date. <br /> A. General Information <br /> Facility Name: CRLLC#2705446 Bldg. No.: <br /> Site Address: 1403 COUNTRY CLUB BLVD City: STOCKTON Zip: 95204 <br /> Facility Contact Person: ARMEN MKRTYTCHIAN Contact Phone No.: (925)884-0800 <br /> Make/Model of Monitoring System: VEEDER-ROOT TLS-350I Date of Testing/Servicing: MAY 13, 2010 <br /> B. Inventory of Equipment Tested/Certified <br /> F <br /> ro riate boxes to indicates ecific a ui ment ins ected/serviceIESEL Tank ID:87 <br /> auging Probe. Model:MAG Z In-Tank Gauging Probe. Model:MAG <br /> Space or Vault Sensor. Model:303 Z Annular Space or Vault Sensor. Model:303 <br /> mp/Trench Sensor(s). Model: 208 Z Piping Sump/Trench Sensor(s). Model:208 <br /> Sensor(s). Model: ❑Fill Sump Sensor(s). Model: <br /> Z Mechanical Line Leak Detector. Model:LD 2000 Z Mechanical Line Leak Detector. Model:LD 2000 <br /> ❑Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> Z Tank Overfill/High-Level Sensor. Model:FLAPPER/FLOAT Z Tank Overfill/High-Level Sensor. Model:FLAPPER/FLOAT <br /> ❑Other(specifyequipment e and model in Section E on Pa e 2 . ❑Other s ecify e ui ment ty e and model in Section E on Pa e 2). <br /> Tank ID:91 Tank ID: <br /> Z In-Tank Gauging Probe. Model:MAG ❑ In-Tank Gauging Probe. Model: <br /> Z Annular Space or Vault Sensor. Model:303 ❑Annular Space or Vault Sensor. Model: <br /> Z Piping Sump/Trench Sensor(s). Model:208 ❑Piping Sump/Trench Sensor(s). Model: <br /> ❑Fill Sump Sensor(s). Model: ❑Fill Sump Sensor(s). Model: <br /> Z Mechanical Line Leak Detector. Model: LD 2000 ❑Mechanical Line Leak Detector. Model: <br /> ❑Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> Z Tank Overfill/High-Level Sensor. Model:FLAPPER/FLOAT [I Tank Overfill/High-Level Sensor. Model: <br /> ❑Others eci equipment e and model in Section E on Page 2 . ❑Other(s eci e ui ment type and model in Section E on Pae 2 . <br /> Dispenser ID: 1_2 Dispenser ID:334 <br /> ❑Dispenser Containment Sensor(s). Model: ❑Dispenser Containment Sensor(s). Model: <br /> Z Shear Valve(s). <br /> Z <br /> Dispenser Containment Floats and Chains . ®Shear Valve(s). <br /> Z Dis enser Containment Floats and Chain (s). <br /> Dispenser ID:5_6 Dispenser ID: 7®8 <br /> ❑Dispenser Containment Sensor(s). Model: ❑Dispenser Containment Sensor(s). Model: <br /> Z Shear Valve(s). Z Shear Valve(s). <br /> Z Dispenser Containment Floats and Chains . Z Dispenser Containment Floats and Chains . <br /> Dispenser ID: Dispenser ID: <br /> ❑Dispenser Containment Sensor(s). Model: ❑Dispenser Containment Sensor(s). Model: <br /> ❑Shear Valve(s). ❑Shear Valve(s). <br /> ❑ <br /> Dispenser Containment Float(s)and Chains . ❑Dis enser Containment Floats and Chain (s). <br /> *If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines. Attached to the Certification is information(e.g. manufacturers' checklists)necessary to verify that this information is correct and a <br /> Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports,I have also attached a copy of the <br /> report; (check all that apply): Z System set-up Z Alarm history report <br /> Technician Name(print): MIKE LAWRENCE :]:S:Zignature: <br /> Certification No:A26642 License: 803705 <br /> Testing Company Name: TANK-TEK ENVIRONMENTAL CORPORATION Phone No: (707)446-6151 <br /> Address: 607 ELMIRA RD, PMB 336, VACAVILLE, CA 95687 Date of Testin /Servicin MAY 13, 2010 <br /> Page 1 of 3 <br /> Monitoring System Certification <br />