COMPLIANCE INFO_2011-2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COUNTRY CLUB
>
1403
>
2300 - Underground Storage Tank Program
>
PR0231995
>
COMPLIANCE INFO_2011-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/18/2023 11:55:25 AM
Creation date
6/3/2020 9:56:19 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2012
RECORD_ID
PR0231995
PE
2361
FACILITY_ID
FA0006438
FACILITY_NAME
United # 5446
STREET_NUMBER
1403
Direction
W
STREET_NAME
COUNTRY CLUB
STREET_TYPE
BLVD
City
STOCKTON
Zip
95204
APN
12323246
CURRENT_STATUS
01
SITE_LOCATION
1403 W COUNTRY CLUB BLVD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231995_1403 W COUNTRY CLUB_2011-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
284
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
State Water Resources Control jLpard Page 1 of 2 <br />16 <br />Home >> Water Issues .* Programs >> Ust >> Leak Prevention ••» Lg113 >> Vendors <br />UST P! ®pgr S - LG 113 <br />.................................................................................................................................................. <br />Issue Date: November 22, 1995 <br />Revision Date: April 8, 2011 <br />Veeder-Root <br />ILS -250, ILS -350, TLS -250i, 2501 Plus, 300, 300C, 300i, 300PC, TLS -350 Series, TLS -450 Series, Red Jacket ProMax and ProPlus <br />with Interstitial Liquid Sensor for Fiberglass Tanks 794390-401, 404, 407, 409, Interstitial Liquid Sensor for Steel Tanks 794390- <br />420, 460, Liquid Sensor for Sumps 794390-206 <br />INTERSTITIAL DETECTOR (LIQUID -PHASE) <br />Detector: <br />Output type: qualitative <br />Sampling frequency: continuous <br />Operating principle: float switch <br />Test Results: <br />synthetic gasoline"* <br />unleaded gasoline* <br />Used Oil** <br />Interstitial Liquid Sensor for Fiberglass Tanks <br />794390-401, 404, 407, 409 <br />3.45 <br />Response time (min) <br />3.66 <br />N/D**** <br /><1 <br />Recovery time (min) <br /><1 <br />N/D**** <br />1.27 <br />Product activation height (cm) <br />1.28 <br />N/D**** <br />Lower detection limit (cm) <br />1.84 <br />1.65 <br />N/D**** <br />Interstitial Liquid Sensor for Steel Tanks <br />794390-420*****, 460 <br />Response time (min) <br />6.00 <br />6.51 <br /><1 <br /><1 <br />Recovery time (min) <br /><1 <br /><1 <br />3.62 <br />Product activation height (cm) <br />3.67 <br />N/D**** <br />4. 17 <br />Lower detection limit (cm) <br />4.05 <br />2.65 <br />Liquid Sensor for Sumps 794390-206 *** <br />Response time (min) 8.19 8.49 N/D**** <br />Recovery time (min) <1 <1 N/D**** <br />Product activation height (cm) 4.12 3.95 N/D**** <br />Lower detection limit (cm) 4.67 4.36 N/D**** <br />* ILS -250, TLS -250i, 250i Plus <br />** ILS -350, TLS -350 Series <br />***Liquid Sensor for Sumps 794390-206 is no longer manufactured and is not supported by the TLS -450 series console. It was replaced <br />by sensor models 794380-208, 209 which are included on the NWGLDE list <br />**** See Glossary <br />***** This sensor is identified as an interstitial sensor, but will function properly in other containment areas such as containment sumps, <br />contained risers and other contained enclosures. This sensor must be installed at the lowest point of the containment enclosure to insure <br />early detection of liquids. <br />Specificity Results (in addition to above): <br />Activated: diesel, heating oil #2, water. <br />Evaluations determined these sensors' responses to the liquids shown above and those indicated in the following section. Biodiesel <br />blends B6 -B20 meeting ASTM D7647 and biodiesel B100 meeting ASTM D6751 would also produce an alarm if the sensor threshold is <br />exceeded. Responses to these fuels were not determined, but would be expected to be very similar to the diesel responses. <br />http://www.waterboards.ca.gov/water issues/programs/ust/leak_prevention/lg113/vendors/... 6/11/2012 <br />
The URL can be used to link to this page
Your browser does not support the video tag.