My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2017
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COUNTRY CLUB
>
1403
>
2300 - Underground Storage Tank Program
>
PR0231995
>
COMPLIANCE INFO_2013-2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/18/2023 1:49:12 PM
Creation date
6/3/2020 9:56:29 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2017
RECORD_ID
PR0231995
PE
2361
FACILITY_ID
FA0006438
FACILITY_NAME
United # 5446
STREET_NUMBER
1403
Direction
W
STREET_NAME
COUNTRY CLUB
STREET_TYPE
BLVD
City
STOCKTON
Zip
95204
APN
12323246
CURRENT_STATUS
01
SITE_LOCATION
1403 W COUNTRY CLUB BLVD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231995_1403 W COUNTRY CLUB_2013-2017.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
414
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• RECEIVED <br />SWRCB, January 2002 OCT 19 2016 Page_2_of_s_ <br />4. TANK ANNULAR TESTING ENVIRONMENTAL HEALTH <br />Test Method Developed By: ❑ Tank Manufacturer ® Industry Standard gineer <br />❑ Other (Spec) <br />Test Method Used: ❑ Pressure ® Vacuum ❑ Hydrostatic <br />❑ Other (Spec) <br />Test Equipment Used: 0 — 30" VACUUM GAUGES <br />Tank # DIESEL Tank # 87 <br />Equipment Resolution: .5% <br />Tank # 91 Tank # WASTE OIL <br />Is Tank Exempt From Testing?' <br />0 Yes ❑ No <br />® Yes ❑ No <br />® Yes ❑ No <br />® Yes ❑ No <br />Tank Capacity: <br />10000 <br />10000 <br />10000 <br />N/A <br />Tank Material: <br />FIBERGLASS <br />FIBERGLASS <br />FIBERGLASS <br />FIBERGLASS <br />Tank Manufacturer: <br />NIA <br />NIA <br />NIA <br />N/A <br />Product Stored: <br />DIESEL <br />87 <br />91 <br />WASTE OIL <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />Test Start Time: <br />Initial Reading (Rj): <br />Test End Time: <br />Final Reading (RF): <br />Test Duration: <br />Change in Reading (RF-Rj): <br />Pass/Fail Threshold or Criteria: <br />NO LOSS <br />NO LOSS <br />NO LOSS <br />NO LOSS <br />Test Result: <br />❑ Pass ❑' Fail <br />❑ Pass, ❑ Fail <br />❑ Pass ❑ Fail` <br />❑ Pass ❑ Fail <br />Was sensor removed for testing? <br />❑ Yes ❑ No ❑ NA <br />[:]Yes ❑ No [:INA <br />❑ Yes ❑ No [INA <br />❑ Yes ❑ No ❑ NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />❑Yes ❑ No ❑ NA <br />[-]Yes❑ No [INA <br />❑Yes []No ❑ NA <br />❑Yes [I No ❑ NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />TANK ANNULARS ARE EXEMPT FROM TESTING <br />1 Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br />containment, such as systems that are hydrostatically monitored or under constant vacuum, are exempt from periodic containment <br />testing. (California Code of Regulations, Title 23, Section 2637(ax6)) <br />
The URL can be used to link to this page
Your browser does not support the video tag.