N V 9 <br /> i <br /> S E R I E S X 7 b <br /> Vertical <br /> Liquid Sensors <br /> Model - <br /> ass <br /> 4 4 <br /> Ronan's Model LS-3 Vertical Liquid Sensor and <br /> the variations LS 3s and LS-ass are designed to detect <br /> 4-1 <br /> All changes in liquid level within reservoirs or the intrusion <br /> of liquid in dry containment zones and caisson compart- <br /> M LS-3 MoU LS-1 ments where vertical positioning of the sensor is allowed. <br /> The LS-3 is constructed of 304 and 315 stainless steel, <br /> polysulfone, Buna--N and PVC. The LS-3s includes an <br /> Typical Applications integral Pull-to-Test cable,required in some jurisdictions. <br /> . DW Steel Tank Interstice Monitoring The LS-3ss Sensor is constructed of 304 and 315 stain- <br /> less steel and Teflon,and is designed for use in chemical <br /> IN Piping Containment Sumps applications where corrosion is a concern.All LS-3 sen- <br /> 4 • Sub-pumpContainment Sumps p sots are designed to provide years of trouble-£tee service. <br /> • Fill Riser Containment Sump AD LS-3 sensors have user selectable logic and may <br /> fff High Levet/Overfill Monitoring be installed in wet or dry conditions. Liquid collection or 3 <br /> • Vertical Application Point Level Sensing loss, sufficient to move the float will transmit a signal to <br /> • Where Ground Level Testing is Required the control panel to initiate control functions or annunci- <br /> ate alarms. The LS-3's resign allows rigid or flexible <br /> • Corrosive Chemical Monitoring <br /> mounting to allow easy periodi <br /> c testing as required by <br /> many regulatory agencies. The sensor may be mounted <br /> LS4 Sensor Switch loosely suspended by its cable or rigid with the 1/2 inch <br /> NPT nipple. <br /> i <br /> cs.3 Senior <br /> Glass g'" ` tdt [� ped- <br /> F IempticaIIy ScaealcDependable, Simple ration <br /> Reed Switch Assembly Ronan's LS-3 Sensors operate on a direct principle. <br /> A, <br /> glass encapsulated hermetically sealed reed switch is <br /> Stem embedded within the sensor stem. Permanent magnets 1 <br /> within the sensors float create a magnetic field which sur- <br /> Mapet rounds the reed switch holding the switch closed.When <br /> Reed the magnetic field is removed by movement of the float, <br /> Switch the reed switch is actuated, thereby changing the state. <br /> Float This condition either opens a closed switch or closes an <br /> open switch. This change in state is then signaled to the <br /> control panel. <br />