My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2017
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COUNTRY CLUB
>
1403
>
2300 - Underground Storage Tank Program
>
PR0231995
>
COMPLIANCE INFO_2013-2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/18/2023 1:49:12 PM
Creation date
6/3/2020 9:56:29 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2017
RECORD_ID
PR0231995
PE
2361
FACILITY_ID
FA0006438
FACILITY_NAME
United # 5446
STREET_NUMBER
1403
Direction
W
STREET_NAME
COUNTRY CLUB
STREET_TYPE
BLVD
City
STOCKTON
Zip
95204
APN
12323246
CURRENT_STATUS
01
SITE_LOCATION
1403 W COUNTRY CLUB BLVD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231995_1403 W COUNTRY CLUB_2013-2017.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
414
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California95205-6232 <br />Telephone., (209) 458-3420 Fax: (209) 468-3433 Web., VVWW.siqov.orq/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />jnited # 5446 <br />Facility Phone: <br />Date: <br />Facility Address: <br />01� 'T <br />0 ��-PY r! El ON, CA 9520-4- <br />- , -, .- IUIR BLMD, STOk",KT <br />CERS ID: <br />Inspection Contact: <br />"Mfs <br />Title: <br />Inspection Type: <br />NiNSPECTION- Operating Permit <br />Program: <br />LIST FACILITY <br />Consent For: <br />Inspection 7xj Photos i Samples <br />ConsentGivenBy: <br />I 'J u <br />Service Technician Onsite: Exp. Date: <br />T <br />Designated Operator: Exp. Date: <br />Service Technician Manufacturer's Training <br />Z2 j <br />CCR= California Code of Regulations HSC =Health and Safety Code CFR= Code of Federal Regulations <br />V = Violation R = Repeat violation COS = Corrected on site during inspection <br />File Review <br />101 <br />HSC 25284 <br />No permit to operate <br />E2 V o R Li COS <br />102 <br />HSC 25284(a)(3) <br />No written agreement between tank owner and tank operator to monitor the tank system <br />Li V o R Li COS <br />103 <br />HSC 25292.2 <br />Current financial responsibility documents not submitted <br />Ei V ii R o COS <br />104 <br />CCR 2711 <br />UST Operating Permit Application for Facility and Tank information not submitted or current <br />Ei V o R Ei COS <br />105 <br />HSC 25286(c) <br />Current BOE number not submitted <br />Ei V c R Li COS <br />106 <br />CCR 2632 <br />Monitoring and response plans not current or approved by the EHD <br />Ei V n R o COS <br />107 <br />CCR 2632(d)(1)(C) <br />Plot plan/site map not submitted or failed to completely show where monitoring is performed <br />c V o R o COS <br />108 <br />CCR 2637(f), 2638(e) <br />Failed to notify the EHD 48 hours prior to conducting testing <br />i:j V o R o COS <br />109 <br />CCR 2637 <br />Failed to test secondary containment <br />Ei V E:i R o COS <br />110 <br />CCR 2637(e) <br />Failed to submit secondary containment test report within 30 days <br />Ei V o R o COS <br />111 <br />CCR 2638(a) <br />Failed to test monitoring and leak detection equipment annually <br />Ej V o R o COS <br />112 <br />HSC 25284.2 <br />Failed to test spill containers annually <br />Ei V Ei R ii COS <br />113 <br />CCR 2638(d) <br />Failed to submit monitoring system certification test report within 30 days <br />[i V o R Ei COS <br />114 <br />CCR 2636(f) <br />Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down <br />o V Ei R o COS <br />115 <br />CCR 2715(a) <br />Failed to inform the EHD of a change of designated operator within 30 days <br />Ei V o R Ei COS <br />116 <br />CCR 2715 <br />Designated operator, service tech or installer did not possess current ICC certification <br />Ei V Ei R o COS <br />117 <br />HSC 25292.5 <br />Failed to conduct ELD testing on a system located within 1000' of a public well <br />Ei V Ei R o COS <br />118 <br />HSC 25292.5 <br />Failed to repair and retest system due to failed ELD test <br />o V o R Ei COS <br />119 <br />CCR 2644.1(a)(5) <br />Failed to submit ELD test results within 60 days <br />[:i V i:i R Li COS <br />120 <br />CCR 2663 <br />Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after <br />o V o R o COS <br />121 <br />CCR 2663 <br />Failed to submit tank lining certification within 30 days or to conduct proper tests <br />D V o R o COS <br />122 <br />HSC 25299 <br />Documents were falsified or misrepresented <br />o V o R ii COS <br />123 <br />CCR 2661 <br />Permit to repair UST system not obtained <br />o V o R c COS <br />124 <br />CCR 2635(d) <br />Failed to submit UST Certification of Installation/Modification <br />o V o R o COS <br />125 <br />CCR 2712(f) <br />Failed to submit a written response within 30 days of receiving an inspection report <br />Ei V o R ii COS <br />126 <br />HSC 25404(e)(4) <br />Failed to report program data electronically <br />u V Ej R o COS <br />Page 1 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.