0 SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, Califomia 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />CONTINUATION FORM <br />Page: 4 of 4 <br />OFFICIAL INSPECTION REPORT <br />Date: 05/20/13 <br />Facility Address: 1403 W Country Club Blvd, Stockton <br />Program: UST <br />SUMMARY OF VIOLATIONS <br />CLASS I, CLASS II, or MINOR -Notice to Comply) <br />206. None of the oil change facility employees have been trained by the designated operator within the <br />past 12 months. The designated operator shall train facility employees for which he or she is <br />responsible in the proper operation and maintenance of the UST system once every 12 months. The <br />training shall include, but is not limited to: <br />1. Operation of the UST system in a manner consistent with the facility's best management practices <br />2. Employee's role with regard to monitoring equipment as specified in the facility's monitoring plan <br />3. Employee's role with regard to spills and overfills as specified in the facility's response plan <br />4. Name of the contact person(s) for emergencies and monitoring equipment alarms <br />Ensure that employees, including the oil change facility employees, have been trained by the designated <br />operator, maintain the list on site, and submit a copy of the training records to the EHD by June 20, <br />2013. <br />305. The dispenser 1/2 east float and chain failed to stop the flow of product at the dispenser when <br />tested. All monitoring equipment shall be maintained to activate an audible and visual alarm or stop the <br />flow of product at the dispenser when it detects a leak. The technician adjusted the chain to repair the <br />device and a retest passed. Violation resolved. <br />305. The dispenser 1/2 diesel product shear/impact valve did not close when tested. All monitoring <br />equipment shall be maintained to activate an audible and visual alarm or stop the flow of product at the <br />dispenser when it detects a leak. Correct immediately by having a properly licensed, trained, and <br />certified contractor replace the failed component with a functional component (LG 113-x listed, if <br />applicable) and obtain a permit within one business day from the EHD. If the failed component can't be <br />replaced immediately, there is a possibility that the UST system may be red tagged to prevent fuel <br />inputs. <br />Note: Complete and submit a copy of the Return to Compliance Certification form with a statement of <br />how each violation was corrected, including supporting documentation, by June 20, 2013. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY, THE ABOVE NOTED DATES LL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REI ECTION AT ANYTIME AT HD'S CURRENT HOURLY RATE. <br />EHD Inspector.Rete <br />Ti 7 '7 <br />Garrett Backus (209) 468-2986 <br />� v <br />EHD 23-02-003 Rev 04119/12 CONTINUATION FORM <br />