Laserfiche WebLink
0 <br />r <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />Date: <br />UNITED 5446 <br />1403 W COUNTRY CLUB BLVD, STOCKTON <br />May 01, 2017 <br />SUMMARY�OF VIOLATIONS <br />(GLASS I, CLASSII; or MINOR: Notice:to Comply) <br />f <br />Remarks <br />105 <br />CCR 2632(d)(1) Failed to have an approved UST monitoring plan. <br />The monitoring plan is not current and/or not approved by the EHD. <br />For tanks TA0199610 (87 grade), TA0199588 (91 grade) and TA0199509 (Diesel), under TANK MONITORING IS <br />PERFORMED USING THE FOLLOWING METHODS, under SECONDARY CONTAINMENT SYSTEM, change <br />"dry" to "wet." <br />For tank TA0199510 (87 grade), under PIPE MONITORING IS PERFORMED USING THE FOLLOWING <br />METHODS, a tine leak detector box needs to be marked "yes." <br />Immediately log into CERS, make the necessary changes, and submit for review by the EFID. <br />Co r ricc.+-e-b of 7 -7 <br />This is a Class II violation. <br />206 <br />CCR 2712 Failure to comply with UST operating permit conditions. <br />Two liquid sensors were replaced around May 25, 20'16 according to Debby of Armour Petroleum (SJCEHD file <br />notes). A permit was not obtained from the EHD. At that time, repair permits were required for sensor replacement. <br />Immediately obtain a permit from the EHD for the replaced liquid sensors. A"Failure to Obtain a Permit" penalty <br />applies making the total permit fee to be $417'2=$834 fda Sar I�1C(�lAt..,. t/i— <br />Avol <br />This is a Class If violation. 7 J 7 q <br />9308 <br />CCR 2636(f) Failed to maintain a continuous monitoring system that activates an audible and visual alarm. <br />The 91 product piping Bravo Float and Chain (F+C) in the UDC sumps failed to stop the flow of product at the 1/2 <br />dispenser (center F+C) and the 3/4 dispenser (east F+C) when tested. The F+C in the 1/2 dispenser was retested <br />by the service technician and passed. <br />The 3/4 dispenser (F+C) failed and was not corrected. Correct immediately by having a property licensed, trained, <br />and certified contractor replace the failed component with a functional component (LG 113-x listed, if applicable) <br />and obtain a permit within one business day from the EHD. If the failed component can't be replaced immediately, <br />there is a possibility that the 91 grade UST system may be red tagged to prevent fuel inputs, <br />t� <br />This Class II <br />is a violation. <br />3 <br />NSC 252.90.1, 25290.2, 25291 Failed to have secondary containment or secondary containment not tight.�� <br />The October 6,2016 secondary containment test results indicate a failure at the 87 STP sump. All secondary <br />containment for the UST system must be tight. Apply for a repair permit with the EHD since the test failure does not <br />appear to be a product piping test boot failure. The 87 product piping pressure test passed. immediately have a <br />properly licensed, trained, and certified contractor repair or replace the failed component under permit and inspect <br />of the EHD. Go trGvl-+c Z <br />This is a Class II violation- <br />Overall Inspection Comments: <br />The routine and monitoring system certification inspection was incomplete. <br />The inspection could not be completed at this time. The technicians were not aware of the used oil tank on the <br />FA0006428 11R0231995 tit:Ot11 05V12017 <br />L_HD 2301 Rev 00/22/16 Page 4 of 5 Underground Storage Tank Prc9rarn OR <br />