My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1999-2010
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3250
>
2300 - Underground Storage Tank Program
>
PR0232224
>
COMPLIANCE INFO_1999-2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2021 10:42:38 AM
Creation date
6/3/2020 9:56:35 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1999-2010
RECORD_ID
PR0232224
PE
2361
FACILITY_ID
FA0001877
FACILITY_NAME
AM PM HAMMER/I5 FOOD #83113
STREET_NUMBER
3250
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95209
APN
08240009
CURRENT_STATUS
01
SITE_LOCATION
3250 W HAMMER LN
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232224_3250 W HAMMER_1999-2010.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
437
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page 6 <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By: ❑ Sump Manufacturer Industry Standard ❑X Professional Engineer <br /> El Other (Specify) <br /> Test Method Used: ❑ Pressure ❑ Vacuum X❑ Hydrostatic <br /> Other (Specify) <br /> Test Equipment Used: VPLT Equipment Resolution: VPLT TO GPH <br /> Sump# 1 REG Sump# Sump# Sump# <br /> T777 <br /> 42"6011 <br /> Sump Material: FIBERGLASS <br /> Height from Tank Top to Top of 1711 <br /> Highest Piping Pentration: <br /> Height from Tank Top to Lowest 3111 <br /> Electrical Pentration: <br /> Condition of sump prior to testing: GOOD <br /> Portion of Sump Tested: 1 1911 <br /> Does turbine shut down when <br /> sump sensor detects liquid(both R❑Yes❑No❑N Dyes[::]NoON E]Yes❑NoON Yes[:]Nowt <br /> product and water)?* <br /> Turbine shutdown response time: 2-5 SEC <br /> Is system programmed for fail-safe ❑ o[ ❑ ❑ � [:] <br /> ❑ � ❑ ❑ <br /> shutdown?* Yes N N Yes N N Yes N N Yes No <br /> Was fail-safe verified to be ❑ ❑ � ❑ ❑ ❑ � ❑ � <br /> operational?* Eyes N N Yes N N X❑Yes N N X Yes No V <br /> Wait time between applying <br /> pressure/vacuum/water and starting 5MIN <br /> test: <br /> Test Start Time: 13 :25 <br /> Initial Reading(Rl): 9.223 <br /> Test End Time: 13 :55 <br /> Final Reading(RF}: 9.000 <br /> Test Duration: 3 0MIN <br /> Change in Reading(RF-Rl ): .01gph <br /> Pass/Fail Threshold or Criteria: .05gph <br /> Was sensor removed for testing? Yes N NA Yes[7]NoE]NA E]YesE]N NA Yes NoE]N <br /> Was sensor properly replaced and F-7-1 <br /> � ❑ � � ❑ � C ❑ ❑ <br /> verified functional after testing? Ye N NA Ye N NA Ye N NA Yes N <br /> Comments- (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> 1 If the entire depth of the sump is not tested,specify how much was tested.If the answer to any f the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire sump must be tested. (See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.